JVC GY-DV500U GY-DV500 User Manual - PDF (4,089KB) - Page 67

VCR Setup Menu Cont'd

Page 67 highlights

12-1 VCR Setup Menu (Cont'd) DISPLAYING AND SETTING VCR SETUP MENUS 12. SETUP MENU FILTER 1 3200k 2 5600k 3 5600k+ND SHUTTER STATUS MENU ALARM MONITOR AUTO IRIS FULL AUTO BLACK BACK L NORMAL SPOT L STRETCH NORMAL COMPRESS LOLUX PRST A B ON KNEE OFF AUTO BARS CAM HML SAVE STBY VTR GAIN OUTPUT WHT.BAL NG POWER ON OFF OPERATE/WARNING RESET MONITOR SELECT CH-1 AUDIO CH-2 LEVEL LIGHT ON OFF COUNTER CTL TC UB "MENU" indication Viewfinder 000 100 200 300 400 500 HM : SERVO / SYSTEM : V I DEO : AUD I O : SYSTEM : T I ME CODE : ON SCREEN : HOUR METER GROUP menu screen Counter display 2 4 4 : LOW CUT 2 4 5 : SAMP L E RATE 2 4 6 : FRONT VOLUME OF F 48K ENAB L E Item menu screen DATA SET DATA SET display CH-1 AUDIO LEVEL CH-2 LITHIUM BATT. CH-1 CH-2 TC GENERATOR AUTO MANUAL PRESET REGEN AUDIO SELECT FREE REC AUDIO INPUT CH-1 CH-2 CONTINUE MENU FRONT REAR GROUP HOLD ITEM SELECT DATA SET SHIFT ADVANCE PRESET 1. 6. 2. 4. 3. 5. 1. Engaging the VCR Setup Menu mode. Press the MENU button. • The "MENU" indication in the display section starts blinking and the VCR Setup Menu appears in the viewfinder and on the counter display. Note: When a cable is connected to the VTR REMOTE connector, the VTR Setup Menu is not displayed in the viewfinder. 2. Selecting the GROUP. Press the GROUP button. • Each time the GROUP button is pressed the selected GROUP number is shown blinking on the viewfinder screen. The counter display shows the selected group. 3. Open the Item menu of the selected GROUP. Press the SELECT button. 4. Selecting the Item. Press the ITEM button. • Each time the ITEM button is pressed the selected item number is shown blinking on the viewfinder screen. The counter display shows the selected item. 5. Changing the setting value of the item. Press the SELECT button and select the setting value. Ⅲ When multiple items should be set, repeat the operations of steps 4. and 5. Ⅲ To set menu items in other groups, press the MENU button. When the relevant group menu is displayed, perform the setting. Ⅲ When the GROUP button is pressed, the items of the higher order group menu are displayed. 6. Saving the setting value. Press the DATA SET button. • "DATA SET" appears in the viewfinder and on the counter display and the setting value is saved in the GY-DV500's memory. The display returns to the normal screen mode when data has been saved. Ⅲ If the MENU button is pressed without pressing the DATA SET button, the display returns to the normal screen mode without the setting value being changed. 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

67
12. SETUP MENU
DISPLAYING AND SETTING VCR SETUP MENUS
1.
Engaging the VCR Setup Menu mode.
Press the MENU button.
The "MENU" indication in the display section starts
blinking and the VCR Setup Menu appears in the
viewfinder and on the counter display.
2.
Selecting the GROUP.
Press the GROUP button.
Each time the GROUP button is pressed the selected
GROUP number is shown blinking on the viewfinder
screen. The counter display shows the selected group.
3.
Open the Item menu of the selected GROUP.
Press the SELECT button.
4.
Selecting the Item.
Press the ITEM button.
Each time the ITEM button is pressed the selected item
number is shown blinking on the viewfinder screen. The
counter display shows the selected item.
5.
Changing the setting value of the item.
Press the SELECT button and select the setting value.
n
When multiple items should be set, repeat the operations
of steps
4.
and
5
.
n
To set menu items in other groups, press the MENU
button. When the relevant group menu is displayed,
perform the setting.
n
When the GROUP button is pressed, the items of the
higher order group menu are displayed.
6.
Saving the setting value.
Press the DATA SET button.
"DATA SET" appears in the viewfinder and on the counter
display and the setting value is saved in the GY-DV500's
memory. The display returns to the normal screen mode
when data has been saved.
n
If the MENU button is pressed without pressing the DATA
SET button, the display returns to the normal screen mode
without the setting value being changed.
GROUP menu screen
Viewfinder
Item menu screen
DATA SET display
Counter display
000
: SERVO / SYSTEM
100
: V I DEO
200
: AUD I O
300
: SYSTEM
400
: T I ME
CODE
500
: ON
SCREEN
HM
: HOUR METER
244 : LOW CUT
OFF
2 4 5 : SAMP L E
RATE
48K
2 4 6 : FRONT
DATA
SET
VOLUME
ENABLE
12-1
VCR Setup Menu (Cont'd)
LIGHT
ON
OFF
COUNTER
CTL
TC
UB
RESET
OPERATE/WARNING
MONITOR
SELECT
STATUS
SHUTTER
MENU
FILTER
1
3200k
2
5600k
3
5600k+ND
POWER
NG
GAIN
OUTPUT
WHT.BAL
VTR
ON
OFF
ALARM
MONITOR
CH-1
CH-2
AUDIO
LEVEL
AUTO IRIS
LOLUX
BACK L
NORMAL
SPOT L
STRETCH
NORMAL
COMPRESS
FULL AUTO BLACK
TC GENERATOR
FREE
REC
PRESET
REGEN
CH-1
CH-2
CH-1
CH-2
CH-1
CH-2
CONTINUE
MENU
PRESET
ADVANCE
SHIFT
HOLD
AUTO
MANUAL
FRONT
REAR
DATA SET
SELECT
ITEM
GROUP
AUDIO SELECT
AUDIO INPUT
AUDIO
LEVEL
LITHIUM BATT.
"MENU" indication
2.
3. 5.
4.
6.
1.
Note:
When a cable is connected to the VTR REMOTE connector,
the VTR Setup Menu is not displayed in the viewfinder.