Lexmark Multifunction Laser C77x - Menus and Messages Guide - Page 36

Standard USB or USB <x>, the Setup Menu if PCL SmartSwitch is - printer for mac

Page 36 highlights

Using the MFP menus Menu item Mac Binary PS Purpose Configures the MFP to process Macintosh binary PostScript print jobs. Values and descriptions On The MFP processes raw binary PostScript print jobs from computers using the Macintosh operating system. Note: This setting often causes Windows print jobs to fail. Off The MFP filters PostScript print jobs using standard protocol. Auto* The MFP processes print jobs from computers using either Windows or Macintosh operating systems. Standard USB or USB These menus are only shown if a USB port is available. Use these menu items to change printer settings affecting a Universal Serial Bus (USB) port (USB ). x represents 1 or 2. Menu item PCL SmartSwitch PS SmartSwitch NPA Mode Purpose Values and descriptions Configures the MFP so it On* automatically switches to PCL emulation when a print job received through the USB port requires it, regardless of the default printer language. Off The MFP examines the data on the USB port and selects PCL emulation if the data indicates that is the required printer language. The MFP does not examine the incoming data. The MFP uses PostScript emulation to process the job if PS SmartSwitch is On, or uses the default printer language specified in the Setup Menu if PS SmartSwitch is Off. Configures the MFP so it On* automatically switches to PostScript emulation when a print job received through the USB port requires it, regardless of the default printer language. Off The MFP examines data on the USB interface and selects PostScript emulation if the data indicates that is the required printer language. The MFP does not examine the incoming data. The MFP uses PCL emulation to process the job if PCL SmartSwitch is On, or uses the default printer language specified in the Setup Menu if PCL SmartSwitch is Off. Specifies whether the MFP performs the special processing required for bidirectional communication, following the conventions defined in the Network Printing Alliance (NPA) Protocol. Note: Changing this menu item automatically resets the MFP once the menus are exited. It is reset to configure memory, and any permanent resources, such as fonts or macros, are lost. On Off Auto* The MFP performs NPA processing. If data is not in NPA format, it is rejected as bad data. The MFP does not perform NPA processing. The MFP examines the data to determine the format and then processes it appropriately. Network/Ports 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

Network/Ports
36
Using the MFP menus
Standard USB or USB <x>
These menus are only shown if a USB port is available. Use these menu items to change printer settings affecting a
Universal Serial Bus (USB) port (USB <x>). x represents 1 or 2.
Mac Binary PS
Configures the MFP to process
Macintosh binary PostScript print
jobs.
On
The MFP processes raw binary
PostScript print jobs from computers
using the Macintosh operating system.
Note:
This setting often causes
Windows print jobs to fail.
Off
The MFP filters PostScript print jobs
using standard protocol.
Auto*
The MFP processes print jobs from
computers using either Windows or
Macintosh operating systems.
Menu item
Purpose
Values and descriptions
PCL
SmartSwitch
Configures the MFP so it
automatically switches to
PCL emulation when a print job
received through the USB port
requires it, regardless of the default
printer language.
On*
The MFP examines the data on the
USB port and selects PCL emulation if
the data indicates that is the required
printer language.
Off
The MFP does not examine the
incoming data. The MFP uses
PostScript emulation to process the
job if PS SmartSwitch is On, or uses
the default printer language specified
in the Setup Menu if PS SmartSwitch
is Off.
PS SmartSwitch
Configures the MFP so it
automatically switches to
PostScript emulation when a print
job received through the USB port
requires it, regardless of the default
printer language.
On*
The MFP examines data on the USB
interface and selects
PostScript emulation if the data
indicates that is the required printer
language.
Off
The MFP does not examine the
incoming data. The MFP uses
PCL emulation to process the job if
PCL SmartSwitch is On, or uses the
default printer language specified in
the Setup Menu if PCL SmartSwitch is
Off.
NPA Mode
Specifies whether the MFP
performs the special processing
required for bidirectional
communication, following the
conventions defined in the Network
Printing Alliance (NPA) Protocol.
Note:
Changing this menu item
automatically resets the MFP once
the menus are exited. It is reset to
configure memory, and any
permanent resources, such as fonts
or macros, are lost.
On
The MFP performs NPA processing. If
data is not in NPA format, it is rejected
as bad data.
Off
The MFP does not perform NPA
processing.
Auto*
The MFP examines the data to
determine the format and then
processes it appropriately.
Menu item
Purpose
Values and descriptions