McAfee M4050 Troubleshooting Guide - Page 55
of the Fail Open Control Cable, through the Fail Open Bypass - power supply
UPC - 731944582832
View all McAfee M4050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
McAfee® Network Security Platform 6.0 System Fault Messages Fault Port pair is in Bypass Mode. Severity Critical Power supply error Critical Description/Cause Action This fault indicates that the indicated GBIC ports are unable to remain in In-line Mode as configured. This has caused failopen control to initiate and the Sensor is now operating in Bypass Mode. Bypass mode indicates that traffic is flowing through the Fail Open Bypass Switch, bypassing the Sensor completely. Check the health of the Sensor and the indicated ports. Check the connectivity of the Fail Open Control Cable to ensure that the Fail Open Control Module can communicate with the Fail Open Controller in the Sensor's Compact Flash port. (Seen only with Sensors with a If the power supply is in place redundant power supply). This and plugged in to a power fault indicates a loss of power in source, check power to the one of the two power supplies in outlet providing power to the the Sensor (primary or power supply. If the fault secondary). This fault can indicates that there is no indicate that the power supply power and a power has failed; that supply has been interruption is not the cause, inserted, but there is no power to replace the failed power the supply; or that the power supply. Contact McAfee supply has been removed. Technical Support to schedule a replacement unit. Sensor changed to Critical a different model Sensor has been replaced by a different model, which does not match the original model. The alert channel will not be able to establish a connection. Ensure you replace with the same Sensor model (For example: Replace an I-2700 with I-2700, and not with an I4010). Scheduled Vulnerability Manager vulnerability data import failed Critical This message indicates that the vulnerability data import by the Scheduler from Vulnerability Manager database has failed. Refer to error logs for details Sensor changes to Critical a different model A Sensor was replaced with a When replacing a Sensor, different model type (for ensure that you replace it with example, an I-1200 was an identical model (for replaced with an I-1200-FO example, replace an I-1200 (failover only) Sensor). The alert with an I-1200, do not attempt channel will be unable to make a to replace a regular Sensor connection. with a failover-only model, and vice-versa). 46