McAfee M4050 Troubleshooting Guide - Page 73
Fault, Severity, Description/Cause, Action, one Sensor in a failover pair
UPC - 731944582832
View all McAfee M4050 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
McAfee® Network Security Platform 6.0 System Fault Messages Fault Sensor is not initialized Severity Warning Description/Cause Action The Sensor is not properly initialized. Either it is in the process of starting up and is not ready, or the signature set is missing on the Sensor. The Sensor may have just been rebooted and is not up yet. Wait a few minutes to see if this is the issue; if not, check to ensure that a signature set is present on the Sensor. A resetconfig command may have been issued, and the Sensor not yet been reconfigured. Sensor Performance Warning has to on Check NSP operation to bring down the metrics below configured threshold level. , which is the configured threshold of . For example: has to on which is the configured threshold of , then this type of warning will be generated. up Warning SSL decryption keys out of sync Warning System startup in progress; alerts being restored Warning The Sensor has just This message is informational. completed booting and is on- Acknowledge the fault. line. The Manager was unable to update the decryption key on one Sensor in a failover pair, causing the key on one Sensor to be out of sync with the one on its failover peer The Manager will make another attempt to update the key. Ensure that the Sensor is online and in good health. The fault will clear when the Manager successfully pushes the key to the Sensor and both keys are in sync. System startup restored alerts from the archive file. Threat Analyzer may not show all alerts. Threat Analyzer may not show all alerts. 64