Adaptec 5325301728 User Guide - Page 2
Replacing a Disk Drive, Overview of the Procedure
UPC - 753253017287
View all Adaptec 5325301728 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Snap Server 4200/4500 Replacing a Disk Drive Two LEDs-indicating disk drive status and disk drive activity-appear on the front of the enclosure below each disk drive. 1 2 3 4 Status light Activity light 5 6 7 8 If a disk drive fails, the status light below the failed drive glows amber. Status Light Green Green Amber Not lit Activity Light Amber, flashing Not lit Not lit Not lit Condition of Disk Drive Disk drive installed and being accessed Disk drive installed but not being accessed Disk drive installed but not working properly Disk drive removed from its bay Overview of the Procedure • Back up your system contents. • Remove the front bezel. • Physically remove the failed disk drive from its bay in the server and install a replacement. • Replace the front bezel. • Configure the replacement disk drive. Field Service Documentation 1 Copyright © 2007, Adaptec, Inc. All rights reserved. Information in this document is subject to change without notice and does not represent a commitment on the part of Adaptec or any of its subsidiaries.