Brother International BAS-311E Network Users Manual - English - Page 112
board is defective., PROM on the control circuit
View all Brother International BAS-311E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 112 highlights
Chapter 7 Error status Probable causes 1. With error code [E.12], the emergency stop switch is activated, or it is defective. Check/repair/adjust • Check that connector P3 (HEAD) on the control circuit board is securely inserted and the emergency stop switch is correctly wired. Parts to be replaced EM switch assembly 2. With error code [E.21], the machine is malfunctioning. • Check that grounding is securely made and there is no equipment that generates strong electrical noise nearby. Control circuit board 3. With error code [E.60], the panel circuit board is defective. • Turn on the power again. If nothing changes, panel PCB is defective. Panel circuit board 4. With error code [E.61], the • Turn on the power again. If nothing changes, control circuit board is defective. control PCB is defective. Control circuit board 5. With error code [E.90], the power supply voltage has sharply dropped. • Check that the voltage of a socket is within ʶ10% of specified voltage. • Refer to #d1-1, -1, -3 #1 The power lamp does not light when the power is turned on. 6. With error code [E.91], the power supply voltage has sharply risen. 7. With error code [E.c0], the [MT] PROM on the control circuit board is defective. • Refer to #1.1-5 • Refer to #1.1-13 PROM 8. With error code [E.c1], the box cooling fan (at the left when viewed from the front) is defective. 9. With error code [E.c2], the control box has overheated. • Check whether any thread scraps are not entangled in the cooling fan. • Check that connector P10 (FAN-R) on the control circuit board is securely inserted. • Clean the air intake of the control box. • The temperature detector is screwed into the heatsink on the control circuit board. Turn on the power after the temperature of the heatsink falls. If the error still appears, the control circuit board is defective. • Note: If the machine is operating with the control box open, the heatsink will overheat, resultantly, error [E.c2] will occur. Fan motorɹ assembly Control circuit board 10. With error code [E.c3], overcurrent has occurred in Xpulse motor. • Check that connector P7 (XPM) on the control circuit board is securely inserted and the X-pulse motor is securely plugged in. • Refer to #1.1-2 X pulse motor control circuit board 104 BAS-311E.311EL.326E.326EL