Brother International PT-P900W Users Guide - Page 79
Specifying the RS232C Serial Port Settings, Cancel, Baud rate, Bit Length, Parity, Busy Control
View all Brother International PT-P900W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Printing Labels Using P-touch Template Specifying the RS232C Serial Port Settings 6 If you are using a barcode scanner or other device with an RS-232C serial interface, you will need to set the serial communications in the barcode scanner and the P-touch Label Printer to be the same in order to operate reliably. You will also need the serial adapter (optional: PA-SCA-001). Note Refer to the barcode scanner programming reference manual before making these settings. We recommend starting with the barcode scanner factory settings and change the communication settings in the P-touch Label Printer because many barcode scanners are more difficult to program. The factory communication settings for the P-touch Label Printer are shown below. Baud rate [9600] bps Bit Length [8] bits 6 Parity [None] Busy Control [DTR] a Click Communication Settings (B) shown in the previous step d "Specifying settings in the P-touch Template Settings tool". b Change the settings as necessary, and then click [Set]. Note Making the proper communication settings may require trying a few different settings so the Communication Settings box does not close after clicking the [Set] button. After the proper settings have been made, click [Cancel] or the red [x] in the upper right corner to close the Communication Settings box. 69