D-Link DMS-1100 User Manual - Page 55

L2 Features > FDB > Static FDB > Multicast Static FDB

Page 55 highlights

D-Link DMS-1100 Series User Manual and port number. VID (1-4094): Enter the VLAN ID on which the associated unicast MAC address resides. MAC Address: Enter the MAC address to which packets will be statically forwarded or dropped. This must be a unicast MAC address. The fields that can be configured for Unicast Static FDB are described below: Item Description Port / Drop Allows the selection of the port number on which the MAC address entered resides. This option could also drop the MAC address from the unicast static FDB. When selecting Port, select the switch unit and port number. VID (1-4094) Enter the VLAN ID on which the associated unicast MAC address resides. MAC Address Enter the MAC address to which packets will be statically forwarded or dropped. This must be a unicast MAC address. Table 4.34 Click Apply to make the configurations take effect. Click the Delete All button to delete all the entries found in the display table. Enter a page number and click the Go button to navigate to a specific page when multiple pages exist. L2 Features > FDB > Static FDB > Multicast Static FDB The Multicast Static FDB page allows user to view and configure the static multicast forwarding settings on the Switch. Figure 4.56 - L2 Features > FDB > Static FDB > Multicast Static FDB The fields that can be configured for Multicast Static FDB are described below: Item Description From Port / To Port Enter the appropriate port range used for the configuration. VID (1-4094) Enter the VLAN ID of the VLAN the corresponding MAC address belongs to. MAC Address Enter the static destination MAC address of the multicast packets. This must be a multicast MAC address. The format of the destination MAC address is 01-XX-XX-XX-XX-XX. Table 4.35 Click Apply to make the configurations take effect. 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

D-Link DMS-1100 Series User Manual
49
and port number.
VID (1-4094):
Enter
the VLAN ID on which the associated unicast MAC address resides.
MAC Address:
Enter
the MAC address to which packets will be statically forwarded or dropped. This must
be a unicast MAC address.
The fields that can be configured for
Unicast Static FDB
are described below:
Item
Description
Port / Drop
Allows the selection of the port number on which the MAC address
entered resides. This option could also drop the MAC address from the
unicast static FDB. When selecting
Port
, select the switch unit and port
number.
VID (1-4094)
Enter
the VLAN ID on which the associated unicast MAC address
resides.
MAC Address
Enter
the MAC address to which packets will be statically forwarded or
dropped. This must be a unicast MAC address.
Table 4.34
Click
Apply
to make the configurations take effect.
Click the
Delete All
button to delete all the entries found in the display table.
Enter a page number and click the
Go
button to navigate to a specific page when multiple pages exist.
L2 Features > FDB > Static FDB > Multicast Static FDB
The Multicast Static FDB page allows user to view and configure the static multicast forwarding settings on
the Switch.
Figure 4.56 – L2 Features > FDB > Static FDB > Multicast Static FDB
The fields that can be configured for
Multicast Static FDB
are described below:
Item
Description
From Port / To Port
Enter
the appropriate port range used for the configuration.
VID (1-4094)
Enter
the VLAN ID of the VLAN the corresponding MAC address
belongs to.
MAC Address
Enter
the static destination MAC address of the multicast packets. This
must be a multicast MAC address. The format of the destination MAC
address is 01-XX-XX-XX-XX-XX.
Table 4.35
Click
Apply
to make the configurations take effect.