Dell PowerEdge MX7000 EMC OpenManage Enterprise-Modular Edition Version 1.20.1 - Page 80
Port Information, Con Forward Error Correction, FEC Type, CL74-FC, CL91-RS, CL108-RS
![]() |
View all Dell PowerEdge MX7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
To configure FEC: 1. On the Port Information page, expand the physical port group, and select the Ethernet port . 2. Click Configure FEC. The Configure Forward Error Correction window is displayed. 3. Select the FEC Type. The available options are: ● Auto-Applies FEC based on the cable or optic connected ● Off-Disables FEC ● CL74-FC- Configures CL74-RS FEC and supports 25G and 50G ● CL91-RS-Configures CL91-RS FEC and supports 100G ● CL108-RS-Configures CL108-RS FEC and supports 25G and 50G 4. Click Finish to save the changes and return to the Port Information page. 80 Ethernet IO Modules
![](/manual_guide/products/dell-poweredge-mx7000-emc-openmanage-enterprisemodular-edition-version-12010-chassis-users-guide-ac4f9ef/80.png)
To configure FEC:
1.
On the
Port Information
page, expand the physical port group, and select the Ethernet port .
2.
Click Configure FEC.
The
Configure Forward Error Correction
window is displayed.
3.
Select the
FEC Type
.
The available options are:
●
Auto
—Applies FEC based on the cable or optic connected
●
Off
—Disables FEC
●
CL74-FC
— Configures CL74-RS FEC and supports 25G and 50G
●
CL91-RS
—Configures CL91-RS FEC and supports 100G
●
CL108-RS
—Configures CL108-RS FEC and supports 25G and 50G
4.
Click Finish to save the changes and return to the
Port Information
page.
80