Next steps 1. Install the air shroud. 2. Follow the procedure listed in After working inside your system. 3. While booting, press F2 to enter System Setup and check that the processor information matches the new system configuration. 4. Run the system diagnostics to verify that the new processor operates correctly. Expansion cards NOTE: When an expansion card is not supported or missing, the iDRAC and Lifecycle Controller logs an event. This does not prevent your system from booting. However, if a F1/F2 pause occurs with an error message, see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/poweredgemanuals. Expansion card installation guidelines Figure 54. Expansion card slot connectors 1. Slot 1 3. Slot 3 2. Slot 2 4. Slot 4 The following table describes the expansion card riser configurations: Table 20. Expansion card slots supported on the system board PCIe slot Risers Processor connection PCIe slot height Slot 1 (Gen4) N/A Processor 1 Full height PCIe slot length Half length PCIe slot width x4 link in x8 slot Installing and removing system components 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

Next steps
1.
Install the air shroud
.
2.
Follow the procedure listed in
After working inside your system
.
3.
While booting, press
F2
to enter
System Setup
and check that the processor information matches the new system
configuration.
4.
Run the system diagnostics to verify that the new processor operates correctly.
Expansion cards
NOTE:
When an expansion card is not supported or missing, the iDRAC and Lifecycle Controller logs an event. This does
not prevent your system from booting. However, if a F1/F2 pause occurs with an error message, see
Troubleshooting
expansion cards
section in the
Dell EMC PowerEdge Servers Troubleshooting Guide
at
www.dell.com/poweredgemanuals
.
Expansion card installation guidelines
Figure 54. Expansion card slot connectors
1.
Slot 1
2.
Slot 2
3.
Slot 3
4.
Slot 4
The following table describes the expansion card riser configurations:
Table 20. Expansion card slots supported on the system board
PCIe slot
Risers
Processor
connection
PCIe slot height
PCIe slot length
PCIe slot width
Slot 1
(Gen4)
N/A
Processor 1
Full height
Half length
x4 link in x8 slot
Installing and removing system components
67