Denon ADV-700 Owners Manual - Page 82
Last Function Memory, 22. Initialization Of The Microprocessor
View all Denon ADV-700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
ENGLISH 21 LAST FUNCTION MEMORY • This unit is equipped with a last function memory which stores the input and output setting conditions as they were immediately before the power is switched off. This function eliminates the need to perform complicated resettings when the power is switched on. • The unit is also equipped with a back-up memory. This function provides memory storage when the power switch is off and with the power cord disconnected. 22 INITIALIZATION OF THE MICROPROCESSOR When the indication of the display is not normal or when the operation of the unit does not shows the reasonable result, the initialization of the microprocessor is required by the following procedure. 1 Press the power button to set the standby mode, then unplug the set's ON / STANDBY Green power cord from the wall power outlet. c 8 1:02:46 1 DVD TONE 2 Hold the following PLAY (1) button and STOP (2) button, and plug the AC cord into the outlet. 3 Check that the entire display is flashing with an interval of about 1 second, and release your fingers from the 2 buttons and the microprocessor will be initialized. 1 22 NOTES: • If step 3 does not work, start over from step 1. • If the microprocessor is reset, all the buttons and the setup settings are reset to the factory default values. 82