Easy Setup and Operation Starting Auto Setup 1 Press the SETUP button. • The "System Setup Menu" appears. 2 Press the CURSOR D or H button to select the "Auto Setup / Room EQ", then press the ENTER button. • The "Auto Setup / Room EQ" menu screen appears. Power Amp Assign The AVR-3806 has available surround back amplifier channel. If no surround back speakers are used in the main room, their amplifier channels can be assigned for multi-zone use or the front speaker's Bi-Amp connection. If this functionality is not needed, skip this "Power Amp Assign" procedure and proceed to "Preliminary Measurements". Press the CURSOR D or H button to select the "Power Amp Assign", then press the CURSOR F or G button to select the "Surround Back", "Front", "Front B", "ZONE2" or "ZONE3". Easy Setup and Operation Preliminary measurements • This procedure is used to automatically determine the background noise, whether or not speakers are connected, and the polarities of the connected speakers. • To avoid affecting the measurements, turn off the airconditioner or any other device that makes noise and take the measurements with the room as quiet as possible. • The set measures the background noise even when in the silent state with no test tones being output, so keep as quiet as possible until the measurements are completed. 1 Press the CURSOR D or H button to select the "Start", then press the CURSOR F button. • The preliminary measurements start. 3 Press the CURSOR D or H button to select the "Auto Setup", then press the ENTER button. • The "Auto Setup" screen appears. The message "Connect Microphone" is displayed if no microphone is connected. If so, connect the auto setup microphone. When "Surround Back" is selected, the surround back channel's test tone during Auto Setup will be output from surround back speakers. When "Front" is selected, change the setting to a Bi-Amp mode for the front speakers. The front channel's test tone during Auto Setup will be output from the front speakers and the surround back speakers. When "Front B" is selected, change the setting to a second stereo output mode. The test tone during Auto Setup will not be output from the surround back speakers. When "ZONE2" or "ZONE3" is selected, change the setting to "ZONE2" or "ZONE3". The test tone during Auto Setup it will not be output to "ZONE2" or "ZONE3" (Another room). The screen shown at the below appears once the preliminary measurements are completed. 2 Press the ENTER button. •The "Speaker Detect Check" screen appears. [ First screen ] 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

11
Easy Setup and Operation
Easy Setup and Operation
Starting Auto Setup
Power Amp Assign
2
Press the
CURSOR
D
or
H
button to select the
“Auto Setup / Room EQ”, then press the
ENTER
button.
• The “Auto Setup / Room EQ” menu screen appears.
Press the
CURSOR
D
or
H
button to select the
“Power Amp Assign”, then press the
CURSOR
F
or
G
button to select the “Surround Back”, “Front”,
“Front B”, “ZONE2” or “ZONE3”.
1
Press the
SETUP
button.
• The “System Setup Menu” appears.
The AVR-3806 has available surround back amplifier channel. If
no surround back speakers are used in the main room, their
amplifier channels can be assigned for multi-zone use or the front
speaker‘s Bi-Amp connection. If this functionality is not needed,
skip this “Power Amp Assign” procedure and proceed to
“Preliminary Measurements”.
The message “Connect Microphone” is displayed if no
microphone is connected. If so, connect the auto setup
microphone.
3
Press the
CURSOR
D
or
H
button to select the
“Auto Setup”, then press the
ENTER
button.
• The “Auto Setup” screen appears.
When “Surround Back” is selected, the surround back
channel‘s test tone during Auto Setup will be output from
surround back speakers.
When “Front” is selected, change the setting to a Bi-Amp
mode for the front speakers.
The front channel‘s test tone during Auto Setup will be
output from the front speakers and the surround back
speakers.
When “Front B” is selected, change the setting to a second
stereo output mode.
The test tone during Auto Setup will not be output from the
surround back speakers.
When “ZONE2” or “ZONE3” is selected, change the
setting to “ZONE2” or “ZONE3”.
The test tone during Auto Setup it will not be output to
“ZONE2” or “ZONE3” (Another room).
Preliminary measurements
• This procedure is used to automatically determine the
background noise, whether or not speakers are connected, and
the polarities of the connected speakers.
•To avoid affecting the measurements, turn off the air-
conditioner or any other device that makes noise and take the
measurements with the room as quiet as possible.
• The set measures the background noise even when in the
silent state with no test tones being output, so keep as quiet as
possible until the measurements are completed.
2
Press the
ENTER
button.
•The “Speaker Detect Check” screen appears.
[ First screen ]
1
Press the
CURSOR
D
or
H
button to select the
“Start”, then press the
CURSOR
F
button.
• The preliminary measurements start.
The screen shown at the below appears once the