Epson 890N Service Manual - Page 24
EPSON FX-890/2190, Revision B, PRODUCT DESCRIPTIONS, Interface, Data transmission timing - fx self test
![]() |
UPC - 010343850019
View all Epson 890N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
EPSON FX-890/2190 Data transmission timing DATA -STROBE BUSY -ACKNLG data byte n t hold t setup t stb data byte n+1 t next t ready t busy t reply t ack t nbusy Figure 1-7. Data transmission timing Table 1-26. Parameters Parameter t setup Minimum 500 nsec t hold 500 nsec t stb 500 nsec t ready 0 t busy _ t reply _ t ack 500 nsec t nbusy 0 t next 0 t tout*1 _ t tin*2 _ Note "*1": Rise and fall time of output signals "*2" : Rise and fall time of input signals Maximum _ _ _ _ 500 nsec _ 10 us _ _ 120 nsec 200 nsec Revision B BUSY signal is active (high level) under any of the following conditions: In the process of receiving data Input buffer full -INT signal active (low level) During hardware initialization -ERROR or PE signal active (low level or high level, respectively) In the self test mode In the adjustment mode In the default-setting mode -ERROR signal is active (low level) under any of the following conditions: In the condition of the printer hardware error (fatal error) In the condition of the paper-out error In the condition of the release lever error In the condition of the cover open error In the condition of the paper eject error PE signal is active (high level) under the following condition: In the condition of paper-out error PRODUCT DESCRIPTIONS Interface 24