Epson 890N Service Manual - Page 64

Troubleshooting for Individual Units, Main Component Checking Point - fx 890 printer troubleshooting

Page 64 highlights

EPSON FX-890/2190 Revision B 3.3 Troubleshooting for Individual Units 3.3.1 Main Component Checking Point The following components can be checked with a simple measurement tool, such as a multi-meter, easily. † Motors Motor PF Motor (CN13) CR Motor (CN12) Table 3-15. Motor Coil Resistance Test Points Test Pin Number Test Method* Meter Reading 1 and 3, 2 and 4 Place one lead on pin 1 (pin2) and the other 16.0 Ω ± 10% lead on pin3 (pin 4) on each of the test pins (at 25 °C per to check the two motor phases. one phase) Common pin: 5 Test pins: 1, 2, 3 and 4 Place one lead on pin 5 and the other lead on 2.7 Ω±10% each of the 4 test pins to check the two motor (at 25°C per phase. one phase) Note "*": Set the meter to ohms. Then disconnect the Motor from the Main Board and check it with printer power off. † Printhead „ Test Method : For example, place one lead on pin C1 and the other lead on Test pin 1 to check #1 pin of the Printhead solenoid. Test pin numbers match the printhead solenoid (dot wire) numbers. NOTE: Set the meter to ohms. Then disconnect the Motor from the Main Board and check it with printer power off. „ Specifications : 8.19 ± 0.8 Ω (at 25°C) Common Line C1 C2 C3 C4 Table 3-16. F Corresponding Wires Common Line 1, 7, 13 C5 9 C6 10, 18 C7 6, 12 C8 R Corresponding Wires 2, 5, 11 3, 15 16, 17 4, 8, 14 Note : 1~18: Wire numbers (Refer to "Figure 2-3" in Chapter 2 for wire numbers.) C1~ C8: Common terminals T: Thermistor terminal N: Not used (The contact of the connector and FFC is positioned at the bottom side of the connector.) Figure 3-2. Printhead Connector Pin Assignment Troubleshooting Troubleshooting for Individual Units 64

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

EPSON FX-890/2190
Revision B
Troubleshooting
Troubleshooting for Individual Units
64
3.3
Troubleshooting for Individual Units
3.3.1
Main Component Checking Point
The following components can be checked with a simple measurement tool, such as a
multi-meter, easily.
Motors
Note
“*”:
Set the meter to ohms. Then disconnect the Motor from the Main Board and check it
with printer power off.
Printhead
Test Method
:
For example, place one lead on pin C1 and the other lead on
Test pin 1 to check #1 pin of the Printhead solenoid. Test
pin numbers match the printhead solenoid (dot wire)
numbers.
NOTE:
Set the meter to ohms. Then disconnect the Motor from the Main Board
and check it with printer power off.
Specifications
: 8.19 ± 0.8
(at 25
°
C)
Note :
1~18:
Wire numbers (Refer to “Figure 2-3“ in Chapter 2 for wire numbers.)
C1~ C8:
Common terminals
T:
Thermistor terminal
N:
Not used
(The contact of the connector and FFC is positioned at the bottom side of the
connector.)
Figure 3-2.
Printhead Connector Pin Assignment
Table 3-15.
Motor Coil Resistance Test Points
Motor
Test Pin Number
Test Method*
Meter
Reading
PF Motor
(CN13)
1 and 3,
2 and 4
Place one lead on pin 1 (pin2) and the other
lead on pin3 (pin 4) on each of the test pins
to check the two motor phases.
16.0
± 10%
(at 25
°
C per
one phase)
CR Motor
(CN12)
Common pin: 5
Test pins: 1, 2, 3
and 4
Place one lead on pin 5 and the other lead on
each of the 4 test pins to check the two motor
phase.
2.7
±10%
(at 25
°
C per
one phase)
Table 3-16.
F
R
Common
Line
Corresponding Wires
Common
Line
Corresponding Wires
C1
1, 7, 13
C5
2, 5, 11
C2
9
C6
3, 15
C3
10, 18
C7
16, 17
C4
6, 12
C8
4, 8, 14