EPSON FX-890/2190 1.2.4 Optional Interface Type-B optional interface cards are available. Table 1-29. FX-890 Reply message ESC/P Main-Type MT9p, PW80c110cpi, PRG(Wxxxxx)rev, AP500ma IBM PPDS MT9p, PW80c110cpi, PRG(Wxxxxx)rev, AP500ma Product-Name FX-890 FX-890 Emulation-Type ESCP9, PRPII9, BDC ESCP9, PRPII9, BDC Entity-Type EPSONFX EPSONPRPII9 Table 1-30. FX-2190 Reply message ESC/P Main-Type MT9p, PW136c110cpi, PRG(Wxxxxx)rev, AP500ma IBM PPDS MT9p, PW136c110cpi, PRG(Wxxxxx)rev, AP500ma Product-Name FX-2190 FX-2190 Emulation-Type ESCP9, PRPII9, BDC ESCP9, PRPII9, BDC Entity-Type EPSONFX EPSONPRPII9 Revision B 1.2.5 Type-B Interface communication specification † Reply for Optional command (*: Reply for Type-B I/F Level 2 device: not described in user's manual) Table 1-31. Reply for Optional command Option command number Command name 00h No-operation Reply-A ----- Reply-B ----- 01h Start Hardware Reset Accept* Execute OK* 02h Start Software Reset Reject ----- 03h Send Main System Type Accept Execute OK 04h Send Name Data Reject ----- 05h Inquire Name Data Accept Execute OK 06h Send Product Name Accept Execute OK 07h Send Software Emulation Type Accept Execute OK 08h Complete Buffered Data Accept Execute OK 09h Stop Procedure Reject ----- 0Ah Return Buffered Data Reject ----- 0Bh Send Entity Type Accept Execute OK 0Ch Send Status Accept Execute OK 0Dh Quit Procedure Reject ----- 0Eh Inquire ASCII Message Reject ----- 0Fh Send ASCII Message Accept Execute OK 10h (Reserved) Unknown ----- 11h Send All Entity Type Reject ----- 12h Inquire Protocol Reject ----- 13h (Reserved) Unknown ----- 14h Inquire Emergency Message Accept Execute OK 15h Send Emergency Reply Accept Execute OK 16h-17h (Reserved) Unknown ----- PRODUCT DESCRIPTIONS Interface 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

EPSON FX-890/2190
Revision B
PRODUCT DESCRIPTIONS
Interface
27
1.2.4
Optional Interface
Type-B optional interface cards are available.
1.2.5
Type-B Interface communication specification
Reply for Optional command
(*: Reply for Type-B I/F Level 2 device:
not described in user's manual
)
Table 1-29.
FX-890
Reply message
ESC/P
IBM PPDS
Main-Type
MT9p, PW80c110cpi,
PRG(Wxxxxx)rev, AP500ma
MT9p, PW80c110cpi,
PRG(Wxxxxx)rev, AP500ma
Product-Name
FX-890
FX-890
Emulation-Type
ESCP9, PRPII9, BDC
ESCP9, PRPII9, BDC
Entity-Type
EPSONFX
EPSONPRPII9
Table 1-30.
FX-2190
Reply message
ESC/P
IBM PPDS
Main-Type
MT9p, PW136c110cpi,
PRG(Wxxxxx)rev, AP500ma
MT9p, PW136c110cpi,
PRG(Wxxxxx)rev, AP500ma
Product-Name
FX-2190
FX-2190
Emulation-Type
ESCP9, PRPII9, BDC
ESCP9, PRPII9, BDC
Entity-Type
EPSONFX
EPSONPRPII9
Table 1-31.
Reply for Optional command
Option command
number
Command name
Reply-A
Reply-B
00h
No-operation
-----
-----
01h
Start Hardware Reset
Accept*
Execute OK*
02h
Start Software Reset
Reject
-----
03h
Send Main System Type
Accept
Execute OK
04h
Send Name Data
Reject
-----
05h
Inquire Name Data
Accept
Execute OK
06h
Send Product Name
Accept
Execute OK
07h
Send Software Emulation Type
Accept
Execute OK
08h
Complete Buffered Data
Accept
Execute OK
09h
Stop Procedure
Reject
-----
0Ah
Return Buffered Data
Reject
-----
0Bh
Send Entity Type
Accept
Execute OK
0Ch
Send Status
Accept
Execute OK
0Dh
Quit Procedure
Reject
-----
0Eh
Inquire ASCII Message
Reject
-----
0Fh
Send ASCII Message
Accept
Execute OK
10h
(Reserved)
Unknown
-----
11h
Send All Entity Type
Reject
-----
12h
Inquire Protocol
Reject
-----
13h
(Reserved)
Unknown
-----
14h
Inquire Emergency Message
Accept
Execute OK
15h
Send Emergency Reply
Accept
Execute OK
16h-17h
(Reserved)
Unknown
-----