Epson 890N Service Manual - Page 56
No LED on Control Panel lights up even with power turned - 890 lights
![]() |
UPC - 010343850019
View all Epson 890N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
EPSON FX-890/2190 Revision B 3.2.2 No LED on Control Panel lights up even with power turned on Table 3-4. No LED on Control Panel lights up Step Action and Question Yes No Parts below can be the source of this error (Chapter 4 Disassembly and Assembly) • Fuse • Power Switch • Control Panel (p.72) • Harness of Control Panel • C524MAIN Board (p.74) • C524PSB/PSE/PSH Board (p.76) Fuse Check the electric circuit and printer mechanism, 1 and if they are not short-circuitted, replace the fuse with a new one. Problem solved Go to Step 2 ♦Is the problem solved? Connection with connectors Make sure that the following connectors are connected properly: 2 • Power Supply Board connector (CN1) • Power Supply Board ~ Main Circuit Board (CN2~CN14) Problem solved Go to Step 3 ♦Is the problem solved? Connection of harness of Control Panel Make sure that the connectors of Control Panel ~ 3 Main Circuit Board (CN1 ~ CN20) are connected properly. Problem solved Go to Step 4 ♦Is the problem solved? Harness of Control Panel 4 Replace the harness of the Control Panel with a new one. Replace the harness. Go to Step 5 ♦Is the problem solved? Control Panel 5 Replace the Control Panel with a new one. ♦Is the problem solved? Replace the Control Panel. Go to Step 6 Table 3-4. No LED on Control Panel lights up Step Action and Question Yes No Power Supply Board 6 Replace the Power Supply Board with a new one. ♦Is the problem solved? Replace the Power Supply Go to Step 7 Board. Main Board 7 Replace the Main Board with a new one. ♦Is the problem solved? Replace the Main Board. Go to 3.2.11 Electrical Noise (p.62) 3.2.3 Abnormal operation of Carriage at power on Table 3-5. Abnormal Carriage operation at power on Step Action and Question Yes No Parts below can be the source of this error (Chapter 4 Disassembly and Assembly) • HP (Home Position) Detector (p.78) • Harness of HP Detector • CR Motor (p.81) • C524MAIN Board (p.74) Connection with connectors 1 Make sure that the connectors on the Main Board are connected properly. ♦Is the problem solved? Problem solved Go to Step 2 Defective CR HP Detector 2 Replace the CR HP Detector with a new one. ♦Is the problem solved? Replace the CR HP Detector. Go to Step 3 Defective harness of CR HP Detector 3 Replace the harness of CR HP Detector with a new Replace the one. harness of CR Go to Step 4 HP Detector. ♦Is the problem solved? Defective CR Motor 4 Replace the CR Motor with a new one. ♦Is the problem solved? Replace the CR Motor. Go to Step 5 Main Board 5 Replace the Main Board with a new one. ♦Is the problem solved? Replace the Main Board. Go to 3.2.11 Electrical Noise (p.62) Troubleshooting Troubleshooting Based on Symptoms 56
![](/manual_guide/products/epson-890n-service-manual-6defdea/56.png)