Epson 890N Service Manual - Page 86
PG (Platen Gap) Detector, Release Detector, PG Detector Removal
![]() |
UPC - 010343850019
View all Epson 890N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
EPSON FX-890/2190 4.3.8 PG (Platen Gap) Detector 1. Remove the Printer Mechanism. (p.80) 2. Release the 2 clips attaching the PG detector to the LEFT FRAME in the Printer Mechanism, and remove the detector. (See Figure 4-22) 3. Disconnect the harness from the detector. Revision B 4.3.9 Release Detector 1. Remove the Printer Mechanism. (p.80) 2. Release the 2 clips attaching the Release detector to the FRAME,SUB,RIGHT in the Printer Mechanism, and remove the detector. (See Figure 4-23) 3. Disconnect the harness from the detector. Clips Harness Clips LEFT FRAME PG Detector Harness Figure 4-22. PG Detector Removal Release Lever Detector FRAME,SUB, RIGHT Figure 4-23. Release Detector Removal Disassembly and Assembly Printer Mechanism Disassembly 86
![](/manual_guide/products/epson-890n-service-manual-6defdea/86.png)