HP Integrity Superdome SX1000 SmartSetup Scripting Toolkit Deployment Guide: H - Page 63
Table 6-8 Error Codes, The error file displays the error code, error message, and if possible
View all HP Integrity Superdome SX1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
The error file displays the error code, error message, and if possible, lists the controller, array, or logical drive associated with the error. The format of the error file is as follows: Line1:ACU Configuration Replication Error Line2:ERROR: () Line3:Controller: Slot # | SerialNumber # | WWN # Line4:Array: # Line5: Logical Drive: # Table 6-8 Error Codes Code 0 1 2866 2867 2868 2869 2870 2871 2872 2873 2874 2875 2821 1102 2819 2820 2818 2819 2822 2823 2824 2857 Error Reason Success Success General error Problem spawning ACU process (user is not authenticated to use ACU or ACU is already running). Failure opening capture file '%s' Error opening capture file. Failure opening input file '%s' Error opening input file. Failure opening error file '%s' Error opening error file. '%s' command expected The specified command is missing or in the incorrect place in the file. '%s' is not a supported command The specified command is not a valid scripting command. '%s' is not a Controller command The specified command does not belong in the Controller section of the script file. '%s' is not an Array command The specified command does not belong in the Array section of the script file. '%s' is not a Logical Drive command The specified command does not belong in the LogicalDrive section of the script file. '%s' is not an HBA command A command found in the HBA section is not a valid command for this section. More than one '%s' command The specified command is used more than once in the same cannot exist in the same section section. It should only be used once per section. No controllers detected No controllers were detected. This error applies to input mode only. Slot information is not available Input mode cannot be run on internal controllers without slot information online. For Windows, this means the System Management Driver has to be loaded. Controller '%s' is invalid The controller specified is not specified correctly. Could not detect Controller '%s' The controller specified was not detected. Invalid Method Invalid Method value. Invalid Controller Invalid Controller value. Invalid Read Cache/Write Cache The specified Read Cache/Write Cache Ratio is not supported Ratio either by the controller or the current controller configuration. Invalid Rebuild Priority The specified Rebuild Priority is not supported. Invalid Expand Priority The specified Expand Priority is not supported. Also, this error occurs if the controller does not allow expansion and therefore does not support Expand Priority. Invalid Surface Scan Delay Invalid Surface Scan Delay cpqacuxe 63