HP LH4r HP Netserver DiagTools v1.0x User Guide - Page 48
Faulty Memory Chip
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Chapter 5 Error Message Reference Code 0100h 0101h 0102h 0120h 0130h 0131h 0132h Description ROM read error. DiagTools Error DiagTools Error Parity error at absolute memory location XXXXXXXXh. The pattern written at XXXXXXXXh was qqqqh. The pattern read back from that address was pppph. Parity failure at XXXXXXXXh during pattern test. Faulty Memory Chip is on DIMM socket YYYY. Recommended Action 1. Take ESD precautions and make sure the system board is seated. 2. Check the seating of the voltage regulator module (VRM) if present. 3. Be sure the processor board (if any) is seated. 4. Make sure the CPU chip is seated. 5. Make sure the memory elements (DIMMs) are properly seated. 6. Check system fans. If overheating occurs, chip may shut down. 7. If the system ran with temperature high, let it cool for 30 minutes, then restart. 8. If system repeatedly shows this error, replace the CPU chip or board, as appropriate. Download a new version of DiagTools from the HP web site and run it. If you get the same error, call the HP Customer Care Center. Download a new version of DiagTools from the HP web site and run it. If you get the same error, call the HP Customer Care Center. 1. Visually inspect the memory board to ensure proper seating. 2. Check to see all DIMMs are the correct HP part number. 3. Visually inspect DIMM units to ensure they are properly seated. 4. Check the positions of DIMMs to see that positioning matches that on the technical reference label or card. 5. Examine the support ticket and check for failures. 6. Bring the system down to its minimum memory configuration and rerun the test. 7. Build up the system by halves until the failure is located. 1. Visually inspect the memory board to ensure proper seating. 2. Check to see all DIMMs are the correct HP part number. 3. Visually inspect DIMM units to ensure they are properly seated. 4. Check the positions of DIMMs to see that positioning matches that on the technical reference label or card. 5. Examine the support ticket and check for failures. 6. Bring the system down to its minimum memory configuration and rerun the test. 7. Build up the system by halves until the failure is located. 1. Visually inspect the memory board to ensure proper seating. 2. Check to see all DIMMs are the correct HP part number. 3. Visually inspect DIMM units to ensure they are properly seated. 4. Check the positions of DIMMs to see that positioning matches that on the technical reference label or card. 5. Examine the support ticket and check for failures. 6. Bring the system down to its minimum memory configuration and rerun the test. 7. Build up the system by halves until the failure is located. 1. Visually inspect the memory board to ensure proper seating. 2. Check to see all DIMMs are the correct HP part number. 3. Visually inspect DIMM units to ensure they are properly seated. 4. Check the positions of DIMMs to see that positioning matches that on the 44