HP MSA 1040 HP MSA Events Description Reference Guide (762785-001, March 2014) - Page 25

If the problem is not outside of the storage system, replace the controller module that logged

Page 25 highlights

173 Info. The indicated vdisk has been removed from quarantine. Recommended actions • No action is required. 174 Info. Enclosure or disk firmware update has succeeded, been aborted by a user, or failed. If the firmware update fails, the user will be notified about the problem immediately and should take care of the problem at that time, so even when there is a failure, this event is logged as Informational severity. Recommended actions • No action is required. 175 Info. The network-port Ethernet link has changed status (up or down) for the indicated controller. Recommended actions • If this event is logged indicating the network port is up shortly after the Management Controller (MC) has booted up (event 139), no action is required. • Otherwise, monitor occurrences of this event for an error trend. If this event occurs more than 8 times per hour, it should be investigated. • This event is probably caused by equipment outside of the storage system, such as faulty cabling or a faulty Ethernet switch. • If this event is being logged by only one controller in a dual-controller system, swap the Ethernet cables between the two controllers. This will show whether the problem is outside or inside the storage system. • If the problem is not outside of the storage system, replace the controller module that logged this event. 176 Info. The error statistics for the indicated disk have been reset. Recommended actions • No action is required. 177 Info. Cache data was purged for the indicated missing volume. Recommended actions • No action is required. 181 Info. One or more configuration parameters associated with the Management Controller (MC) have been changed, such as configuration for SNMP, SMI-S, email notification, and system strings (system name, system location, etc.). Recommended actions • No action is required. Event descriptions 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Event descriptions
25
173
Info.
The indicated vdisk has been removed from quarantine.
Recommended actions
No action is required.
174
Info.
Enclosure or disk firmware update has succeeded, been aborted by a user, or failed.
If the firmware update fails, the user will be notified about the problem immediately and should take care
of the problem at that time, so even when there is a failure, this event is logged as Informational severity.
Recommended actions
No action is required.
175
Info.
The network-port Ethernet link has changed status (up or down) for the indicated controller.
Recommended actions
If this event is logged indicating the network port is up shortly after the Management Controller (MC)
has booted up (event 139), no action is required.
Otherwise, monitor occurrences of this event for an error trend. If this event occurs more than 8 times
per hour, it should be investigated.
This event is probably caused by equipment outside of the storage system, such as faulty cabling or
a faulty Ethernet switch.
If this event is being logged by only one controller in a dual-controller system, swap the Ethernet
cables between the two controllers. This will show whether the problem is outside or inside the
storage system.
If the problem is not outside of the storage system, replace the controller module that logged this
event.
176
Info.
The error statistics for the indicated disk have been reset.
Recommended actions
No action is required.
177
Info.
Cache data was purged for the indicated missing volume.
Recommended actions
No action is required.
181
Info.
One or more configuration parameters associated with the Management Controller (MC) have been
changed, such as configuration for SNMP, SMI-S, email notification, and system strings (system name,
system location, etc.).
Recommended actions
No action is required.