HP MSA 1040 HP MSA Events Description Reference Guide (762785-001, March 2014) - Page 39
programmed. Therefore, the MAC address is derived by using the controller's serial number from flash - iscsi requirements
![]() |
View all HP MSA 1040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
269 Info. A partner firmware update operation has started. This operation is used to copy firmware from one controller to the other to bring both controllers up to the same version of firmware. Recommended actions • No action is required. 270 Warning Either there was a problem reading or writing the persistent IP data from the FRU ID SEEPROM, or invalid data were read from the FRU ID SEEPROM. Recommended actions • Check the IP settings (including iSCSI host-port IP settings for an iSCSI system), and update them if they are incorrect. 271 Info. The storage system could not get a valid serial number from the controller's FRU ID SEEPROM, either because it couldn't read the FRU ID data, or because the data in it are not valid or have not been programmed. Therefore, the MAC address is derived by using the controller's serial number from flash. This event is only logged one time during bootup. Recommended actions • No action is required. 272 Info. Expansion of the indicated snap pool has started. Recommended actions • No action is required. 273 Info. PHY fault isolation has been enabled or disabled by a user for the indicated enclosure and controller module. Recommended actions • No action is required. Event descriptions 39
![](/manual_guide/products/hewlettpackard-msa-1040-hp-msa-events-description-reference-guide-762785001-2014-c70e5ec/39.png)