HP MSA 1040 HP MSA Events Description Reference Guide (762785-001, March 2014) - Page 51

The volume is not in the replication set.

Page 51 highlights

435 Warning Failed to initialize the indicated replication set. This can occur because: • Firmware in the remote system is incompatible with firmware in the local system. • The primary volume and secondary volume involved in replication cannot communicate. Recommended actions • Update the firmware on one or both systems so they are running the same version. • Check your network or fabric for abnormally high congestion or connectivity issues. 436 Warning Firmware in the remote system is incompatible with firmware in the local system so they cannot communicate with each other to perform replication operations. Recommended actions • Update the firmware on one or both systems so they are running the same version. 437 Info. Started to change the primary volume for the indicated replication set to the indicated volume. Recommended actions • No action is required. 438 Info. Completed changing the primary volume for the indicated replication set to the indicated volume. The primary volume of the indicated replication set has been changed by a user to a different volume in the replication set. Recommended actions • No action is required. 439 Error Failed to change the primary volume to the indicated volume for the indicated replication set. This can occur for several reasons, such as: • The volume is not in the replication set. • Configuration tag or configuration data not found. • The retry limit has been reached. Recommended actions • Verify that the specified volume is part of the replication set. • Verify that there are no network issues preventing communication between the local and remote storage systems. Event descriptions 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Event descriptions
51
435
Warning
Failed to initialize the indicated replication set.
This can occur because:
Firmware in the remote system is incompatible with firmware in the local system.
The primary volume and secondary volume involved in replication cannot communicate.
Recommended actions
Update the firmware on one or both systems so they are running the same version.
Check your network or fabric for abnormally high congestion or connectivity issues.
436
Warning
Firmware in the remote system is incompatible with firmware in the local system so they cannot
communicate with each other to perform replication operations.
Recommended actions
Update the firmware on one or both systems so they are running the same version.
437
Info.
Started to change the primary volume for the indicated replication set to the indicated volume.
Recommended actions
No action is required.
438
Info.
Completed changing the primary volume for the indicated replication set to the indicated volume.
The primary volume of the indicated replication set has been changed by a user to a different volume in
the replication set.
Recommended actions
No action is required.
439
Error
Failed to change the primary volume to the indicated volume for the indicated replication set. This can
occur for several reasons, such as:
The volume is not in the replication set.
Configuration tag or configuration data not found.
The retry limit has been reached.
Recommended actions
Verify that the specified volume is part of the replication set.
Verify that there are no network issues preventing communication between the local and remote
storage systems.