HP MSA 1040 HP MSA Events Description Reference Guide (762785-001, March 2014) - Page 63
Error
![]() |
View all HP MSA 1040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
524 Error 527 Error 528 Error 529 Error A temperature or voltage sensor reached a critical threshold. A sensor monitored a temperature or voltage in the critical range. When the problem is resolved, event 47 is logged for the component that logged event 524. If the event refers to a disk sensor, disk behavior may be unpredictable in this temperature range. Check the event log to determine if more than one disk has reported this event. • If multiple disks report this condition there could be a problem in the environment. • If one disk reports this condition, there could be a problem in the environment or the disk has failed. Recommended actions • Check that the storage system's fans are running. • Check that the ambient temperature is not too warm. The enclosure operating range is 5-40 C (41 F-104 F). • Check for any obstructions to the airflow. • Check that there is a module or blank plate in every module slot in the enclosure. • If none of the above explanations apply, replace the disk or controller module that logged the error. Expander Controller (EC) firmware is incompatible with the enclosure. As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the short enclosure status page in the supported diagnostic list. Recommended actions • Upgrade the controller module to the latest supported bundle version. Expander Controller firmware detected that the partner Expander Controller (EC) firmware is incompatible with the enclosure. As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the short enclosure status page in the supported diagnostic list. Recommended actions • Upgrade the partner controller module to the latest supported bundle version. The local Expander Controller (EC) is incompatible with the enclosure. As a preventative measure, the Expander Controller (EC) disabled all PHYs and reported the short enclosure status page in the supported diagnostic list. Recommended actions • Replace the controller module with one that is compatible with the enclosure. Event descriptions 63
![](/manual_guide/products/hewlettpackard-msa-1040-hp-msa-events-description-reference-guide-762785001-2014-c70e5ec/63.png)