HP MSA 1040 HP MSA Events Description Reference Guide (762785-001, March 2014) - Page 31
Perform a rescan to repopulate the SAS map.
View all HP MSA 1040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
209 Error A scrub-disk job logged with event 208 has completed and found one or more media errors, SMART events, or hard (non-media) errors. If this disk is used in a non-fault-tolerant vdisk, data may have been lost. Recommended actions • Replace the disk with one of the same type (SAS SSD, enterprise SAS, or midline SAS) and the same or greater capacity. For continued optimum I/O performance, the replacement disk should have performance that is the same as or better than the one it is replacing. Warning A scrub-disk job logged with event 208 has been aborted by a user, or has reassigned a disk block. These bad-block replacements are reported as "other errors". If this disk is used in a non-fault-tolerant vdisk, data may have been lost. Recommended actions • Monitor the error trend and whether the number of errors approaches the total number of bad-block replacements available. Info. A scrub-disk job logged with event 208 has completed and found no errors, or a disk being scrubbed (with no errors found) has been added to a vdisk, or a user has aborted the job. Recommended actions • No action is required. 210 Info. All snapshots have been deleted for the indicated master volume or snap pool. Recommended actions • No action is required. 211 Warning SAS topology has changed; no elements are detected in the SAS map. The message specifies the number of elements in the SAS map, the number of expanders detected, the number of expansion levels on the native (local controller) side and on the partner (partner controller) side, and the number of device PHYs. Recommended actions • Perform a rescan to repopulate the SAS map. • If a rescan does not resolve the problem, then shut down and restart both Storage Controllers. • If the problem persists, see "Resources for diagnosing and resolving problems" (page 5). Info. SAS topology has changed; the number of SAS expanders has increased or decreased. The message specifies the number of elements in the SAS map, the number of expanders detected, the number of expansion levels on the native (local controller) side and on the partner (partner controller) side, and the number of device PHYs. Recommended actions • No action is required. 212 Info. All master volumes associated with the indicated snap pool have been deleted. Recommended actions • No action is required. Event descriptions 31