HP Stitch S1000 User Guide - Page 243
Drop-detector diagnostics, Decision table
View all HP Stitch S1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 243 highlights
The following image is printed. ▲ The image below shows plainly which nozzles in each printhead are printing and not printing. For reference, each one of the 5 areas (square in the picture and 1 to 5) of each color corresponds to approximately 1000 nozzles. Drop-detector diagnostics Execute the drop-detector diagnostics from the Print Care window. This will identify blocked nozzles in each printhead. Decision table The following table summarizes the data that can be seen in each diagnostic, the possible causes, and the decisions. Mid-tones (section 1) No banding Banding in all colors Banding in one color Nozzle health (section 2) Drop detector Possible cause < 300 blocked (all colors) < 300 blocked (all colors) Other < 300 blocked (all colors) < 300 blocked (all colors) Substrate advance, or other < 300 blocked (that color) < 300 blocked (that color) Other Action Continue banding troubleshooting. Check the substrateadvance sensor. Continue banding troubleshooting. Continue banding troubleshooting. ENWW Printheads 237