HP Stitch S1000 User Guide - Page 255
Acoustic specifications, a dusty environment.
View all HP Stitch S1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 255 highlights
Not operating, in transport or storage, ink in tubes Not operating, in transport or storage, no ink in tubes * Temperature range 5 to 55°C (41 to 131°F) -10 to 55°C (26 to 131°F) Humidity range 90% relative humidity at 55°C (131°F) 90% relative humidity at 55°C (131°F) Temperature gradient 10°C/h (18°F/h) or less 10°C/h (18°F/h) or less * If the printer is going to be kept at a temperature of less than 5°C, call your service representative to empty the ink from the tubes. Maximum operating altitude: 3000 m (10000 ft) The printer should not be exposed to direct sunlight or any other strong light source, and it should not be used in a dusty environment. Acoustic specifications Average idle sound pressure at bystander position Average operating sound pressure at bystander position < 52 dB (A) < 64 dB (A) Exhaust specifications The aerosol extractor provided contains only passive elements. The exit exhaust, diameter 114 mm (4.5 in), should be connected to the customer's exhaust installation, ensuring a minimum airflow of 300 m³/h and a minimum pressure of −1500 Pa, measured at the printer's aerosol-extractor exhaust. HP recommends using the exhaust system independent from the application. However, for specific applications where the ink collector is needed, the exhaust system must be connected. In addition, HP recommends conducting the exhaust air outside the room. ENWW Acoustic specifications 249