Figure 8.2 IORDY Timing Read Data Valid DIOR-/DIOW- tA tB IORDY SYMBOL Description tA IORDY Setup Time tB IORDY Pulse Width tRD Read Data Valid to IORDY active tc IORDY assertion to release tRD tC MIN(ns) 0 MAX(ns) 35 1250 5 K6610170 Rev.2 Dec 22, 2004 - 131 -
K6610170
Rev.2
Dec 22, 2004
- 131 -
Figure 8.2 IORDY Timing
SYMBOL
Description
MIN(ns)
MAX(ns)
t
A
IORDY Setup Time
35
t
B
IORDY Pulse Width
1250
t
RD
Read Data Valid to IORDY active
0
tc
IORDY assertion to release
5
t
A
t
B
DIOR-/DIOW-
IORDY
t
RD
Read Data Valid
t
C