Table 28. T&D Error Messages and Actions (continued) Error Message Description Action TD 5 FRU 1 X Operator Panel Failure 1. This error can occur if a key is not pressed in less than 10 seconds. Run T&D05 again to verify the problem. 2. Replace the operator panel. See "Operator Panel" on page 355. 3. Replace the logic board. See "Logic Board - Models 001 and 002" on page 378. For Model 003, see "Logic Board - Model 003" on page 366. 4. Replace the operator panel cable. TD 6 FRU 0 X (*) Parallel Interface Failure Replace the logic board. See "Logic Board - Models 001 and 002" on page 378. For Model 003, see "Logic Board - Model 003" on page 366. TD 8 FRU 0 X Microcode Error Replace the logic board. See "Logic Board - Models 001 and 002" on page 378. For Model 003, see "Logic Board - Model 003" on page 366. TD 10 FRU 0 1 (*) ASF/Stacker Failure 1. Replace the logic board. See "Logic Board - Models 001 and 002" on page 378. For Model 003, see "Logic Board - Model 003" on page 366. 2. Replace the stacker cable assembly. TD 12 FRU 0 X AFTA Failure 1. See "Standard AFTA Service Check and Adjustment" on page 285. 2. Replace the logic board. See "Logic Board - Models 001 and 002" on page 378. For Model 003, see "Logic Board - Model 003" on page 366. TD 14 FRU 0 20 Thermal Sense Failure 1. Replace the printhead. See "Printhead" on page 356. 2. Replace the logic board. See "Logic Board - Models 001 and 002" on page 378. For Model 003, see "Logic Board - Model 003" on page 366. 3. Install new printhead cables. Chapter 2. Diagnostics 232
![](/manual_guide/products/ibm-4247003-maintenance-manual-ab6123f/232.png)