IBM 88631SU Service Guide - Page 134
Drive, Hot-swap
UPC - 000435913135
View all IBM 88631SU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
DVD Drive To remove the DVD drive, complete the following steps. Retention latch 1. Read the safety information that begins on page vii, and "Handling static-sensitive devices" on page 114. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables necessary to replace the device. 3. Remove the top cover and bezel (see "Removing the cover and bezel" on page 115). 4. Pull the blue retention latch forward and pull the DVD drive out of the server. To install a DVD drive, compete the following steps: 1. Slide the DVD drive into the server to engage the drive. 2. Replace the top cover and bezel. 3. Reconnect the external cables and power cords. Hot-swap fan The server comes with 80-mm hot-swap fans in front of the PCI-X slots and 92-mm hot-swap fans in front of the memory cards. The same removal and installation procedures apply to either size fan. When a fan fails or is removed, the other fans in the server speed up to maintain a safe operating temperature in the server until the fan is reinstalled or replaced. When the fan is installed properly the fans will slow down. To remove a hot-swap fan, complete the following steps. 118 IBM System x3850 Type 8863, 7362: Problem Determination and Service Guide