IBM 88631SU Service Guide - Page 150

PCI-X, adapter, guide

Page 150 highlights

5. Note where each cable is connected, and then disconnect all cables from the I/O board and remove the assembly from the server. To install an I/O board, complete the following steps: 1. Connect all cables to the internal connectors on the I/O board. 2. Align the board with the card guides and insert the board in the connector. 3. Close the release latches to seat the board in the connector. 4. Replace the top cover. 5. Reconnect the external cables and power cords. PCI-X adapter guide To remove the PCI-X adapter guide, complete the following steps. Latch mechanism Quarter-turn fasteners 1. Read the safety information that begins on page vii, and "Handling static-sensitive devices" on page 114. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables necessary to replace the device. 3. Remove the top cover. 4. Lift the latch mechanism. 5. Remove all adapters and adapter dividers, and place the adapters on a static-protective surface (see the User's Guide on the IBM Documentation CD). Note: You might find it helpful to note where each adapter is installed before removing the adapters. 6. Disconnect one end of all cables that pass through the PCI-X adapter guide; then, remove the cables from the routing feature of the guide and fold the cables out of the way. Note: You might find it helpful to note where each cable is connected before disconnecting the cables. 7. Turn the blue quarter-turn fasteners to release the PCI-X adapter guide. 8. Lift the guide out of the server. 134 IBM System x3850 Type 8863, 7362: Problem Determination and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188

5.
Note
where
each
cable
is
connected,
and
then
disconnect
all
cables
from
the
I/O
board
and
remove
the
assembly
from
the
server.
To
install
an
I/O
board,
complete
the
following
steps:
1.
Connect
all
cables
to
the
internal
connectors
on
the
I/O
board.
2.
Align
the
board
with
the
card
guides
and
insert
the
board
in
the
connector.
3.
Close
the
release
latches
to
seat
the
board
in
the
connector.
4.
Replace
the
top
cover.
5.
Reconnect
the
external
cables
and
power
cords.
PCI-X
adapter
guide
To
remove
the
PCI-X
adapter
guide,
complete
the
following
steps.
Latch mechanism
Quarter-turn
fasteners
1.
Read
the
safety
information
that
begins
on
page
vii,
and
“Handling
static-sensitive
devices”
on
page
114.
2.
Turn
off
the
server
and
peripheral
devices,
and
disconnect
the
power
cords
and
all
external
cables
necessary
to
replace
the
device.
3.
Remove
the
top
cover.
4.
Lift
the
latch
mechanism.
5.
Remove
all
adapters
and
adapter
dividers,
and
place
the
adapters
on
a
static-protective
surface
(see
the
User’s
Guide
on
the
IBM
Documentation
CD).
Note:
You
might
find
it
helpful
to
note
where
each
adapter
is
installed
before
removing
the
adapters.
6.
Disconnect
one
end
of
all
cables
that
pass
through
the
PCI-X
adapter
guide;
then,
remove
the
cables
from
the
routing
feature
of
the
guide
and
fold
the
cables
out
of
the
way.
Note:
You
might
find
it
helpful
to
note
where
each
cable
is
connected
before
disconnecting
the
cables.
7.
Turn
the
blue
quarter-turn
fasteners
to
release
the
PCI-X
adapter
guide.
8.
Lift
the
guide
out
of
the
server.
134
IBM
System
x3850
Type
8863,
7362:
Problem
Determination
and
Service
Guide