IBM JS20 User Guide - Page 71

IBM JS20 - BladeCenter - 8842 Manual

Page 71 highlights

Checkpoint code E1FB E1FC E1FD E1FE E1FF E199 E200 E201 E202 Description Suggested action Reserved Have the blade server serviced. Build the boot list for serial storage architecture (SSA) adapters. The location code of the SSA adapter being scanned is also displayed. 1. Perform the system checkout procedure. See "System checkout" on page 48. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. E1FD and another progress code (Exxx) will alternate in the operator panel. The other code indicates where the error occurred. 1. Perform the system checkout procedure. See "System checkout" on page 48. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. Build the boot list for Fibre Channel 1. Perform the system checkout procedure. See adapters. The world-wide port "System checkout" on page 48. number (WWPN) of the SAN adapter being scanned is also displayed. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. Building the boot list for Fibre 1. Perform the system checkout procedure. See Channel adapters. The WWPN of the "System checkout" on page 48. SAN adapter being scanned is also displayed. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. Restarting (rebooting) the partition to activate the changes that are specified in the boot-image's executable and linkable format (ELF) header. 1. Check the http://www.ibm.com/support Web site for a later firmware version that might address the problem. For additional information, see "Updating the firmware code for the blade server and the service processor" on page 40. 2. If a later firmware version is not available, or if the problem remains after you update the firmware code, go to the "Boot problem resolution" section in the BladeCenter JS20 Type 8842 Hardware Maintenance Manual and Troubleshooting Guide. Follow the instructions in that section. I2C bus controller initialization. 1. Perform the system checkout procedure. See "System checkout" on page 48. 2. If the problem remains, force the system to start from the PERM flash image to reflash the TEMP image for recovery. See "Recovering the system firmware code" on page 84. 3. If the problem remains, replace the blade server. Contact a service support representative for assistance. The flash random-access memory (RAM) cyclic redundancy check (CRC) checksum is valid. 1. Perform the system checkout procedure. See "System checkout" on page 48. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. Programmable interrupt controller (MPIC) initialization. 1. Perform the system checkout procedure. See "System checkout" on page 48. 2. This error indicates that you might have a problem with the system board. Contact a service support representative for more information. Chapter 7. Solving problems 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132

Checkpoint
code
Description
Suggested
action
E1FB
Reserved
Have
the
blade
server
serviced.
E1FC
Build
the
boot
list
for
serial
storage
architecture
(SSA)
adapters.
The
location
code
of
the
SSA
adapter
being
scanned
is
also
displayed.
1.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E1FD
E1FD
and
another
progress
code
(Exxx)
will
alternate
in
the
operator
panel.
The
other
code
indicates
where
the
error
occurred.
1.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E1FE
Build
the
boot
list
for
Fibre
Channel
adapters.
The
world-wide
port
number
(WWPN)
of
the
SAN
adapter
being
scanned
is
also
displayed.
1.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E1FF
Building
the
boot
list
for
Fibre
Channel
adapters.
The
WWPN
of
the
SAN
adapter
being
scanned
is
also
displayed.
1.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E199
Restarting
(rebooting)
the
partition
to
activate
the
changes
that
are
specified
in
the
boot-image’s
executable
and
linkable
format
(ELF)
header.
1.
Check
the
Web
site
for
a
later
firmware
version
that
might
address
the
problem.
For
additional
information,
see
“Updating
the
firmware
code
for
the
blade
server
and
the
service
processor”
on
page
40.
2.
If
a
later
firmware
version
is
not
available,
or
if
the
problem
remains
after
you
update
the
firmware
code,
go
to
the
“Boot
problem
resolution”
section
in
the
BladeCenter
JS20
Type
8842
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
.
Follow
the
instructions
in
that
section.
E200
I
2
C
bus
controller
initialization.
1.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
2.
If
the
problem
remains,
force
the
system
to
start
from
the
PERM
flash
image
to
reflash
the
TEMP
image
for
recovery.
See
“Recovering
the
system
firmware
code”
on
page
84.
3.
If
the
problem
remains,
replace
the
blade
server.
Contact
a
service
support
representative
for
assistance.
E201
The
flash
random-access
memory
(RAM)
cyclic
redundancy
check
(CRC)
checksum
is
valid.
1.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
E202
Programmable
interrupt
controller
(MPIC)
initialization.
1.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
2.
This
error
indicates
that
you
might
have
a
problem
with
the
system
board.
Contact
a
service
support
representative
for
more
information.
Chapter
7.
Solving
problems
59