IBM JS20 User Guide - Page 85

Setenv/$Setenv

Page 85 highlights

Table 1. Abbreviated list of firmware error codes (continued) Error code Failing device or problem found Suggested action 25A80210 Setenv/$Setenv parameter error; name contains a null character. If the problem remains, replace the battery in the blade server. For additional information, see the Hardware Maintenance and Troubleshooting Guide. Note: After you replace the battery, you must reset the system date and time through the operating system that you installed. 25A80211 Setenv/$Setenv parameter error; value contains a null character. If the problem still remains, replace the system-board assembly. Contact a service support representative for assistance. If the problem remains, replace the battery in the blade server. For additional information, see the Hardware Maintenance and Troubleshooting Guide. Note: After you replace the battery, you must reset the system date and time through the operating system that you installed. 25A80998 NVRAMRC script evaluation error. If the problem still remains, replace the system-board assembly. Contact a service support representative for assistance. Perform the following steps to remove the NVRAMRC script: 1. Boot to the open firmware prompt. 2. Enter the following command: 0 0 " nvramrc" $setenv 25A80999 NVRAMRC script evaluation error; stack unbalanced on completion. If the problem remains, contact your system administrator for assistance. This is a firmware debug environment error. No action is required. No component replacement is required. 25000000 25C00000 The blade server failed to set the Write Delay (WRDLY) bit in the memory controller register. No DIMMs were detected. If the problem remains, have the blade server serviced. 1. Start from the PERM flash image to reflash the TEMP image for recovery. See "Recovering the system firmware code" on page 84. 2. If the problem remains, replace the blade server. Contact a service support representative for assistance. Note: For additional information about DIMMs, see "Installing memory modules" on page 24. 1. Make sure that the DIMMs are correctly seated. If necessary, reseat the DIMMs. 2. Restart the blade server. 3. Perform the system checkout procedure. See "System checkout" on page 48. If the problem remains, replace the system-board assembly. Contact a service support representative for assistance. Chapter 7. Solving problems 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132

Table
1.
Abbreviated
list
of
firmware
error
codes
(continued)
Error
code
Failing
device
or
problem
found
Suggested
action
25A80210
Setenv/$Setenv
parameter
error;
name
contains
a
null
character.
If
the
problem
remains,
replace
the
battery
in
the
blade
server.
For
additional
information,
see
the
Hardware
Maintenance
and
Troubleshooting
Guide.
Note:
After
you
replace
the
battery,
you
must
reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
If
the
problem
still
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
25A80211
Setenv/$Setenv
parameter
error;
value
contains
a
null
character.
If
the
problem
remains,
replace
the
battery
in
the
blade
server.
For
additional
information,
see
the
Hardware
Maintenance
and
Troubleshooting
Guide.
Note:
After
you
replace
the
battery,
you
must
reset
the
system
date
and
time
through
the
operating
system
that
you
installed.
If
the
problem
still
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
25A80998
NVRAMRC
script
evaluation
error.
Perform
the
following
steps
to
remove
the
NVRAMRC
script:
1.
Boot
to
the
open
firmware
prompt.
2.
Enter
the
following
command:
0
0
"
nvramrc"
$setenv
If
the
problem
remains,
contact
your
system
administrator
for
assistance.
25A80999
NVRAMRC
script
evaluation
error;
stack
unbalanced
on
completion.
This
is
a
firmware
debug
environment
error.
No
action
is
required.
No
component
replacement
is
required.
If
the
problem
remains,
have
the
blade
server
serviced.
25000000
The
blade
server
failed
to
set
the
Write
Delay
(WRDLY)
bit
in
the
memory
controller
register.
1.
Start
from
the
PERM
flash
image
to
reflash
the
TEMP
image
for
recovery.
See
“Recovering
the
system
firmware
code”
on
page
84.
2.
If
the
problem
remains,
replace
the
blade
server.
Contact
a
service
support
representative
for
assistance.
25C00000
No
DIMMs
were
detected.
Note:
For
additional
information
about
DIMMs,
see
“Installing
memory
modules”
on
page
24.
1.
Make
sure
that
the
DIMMs
are
correctly
seated.
If
necessary,
reseat
the
DIMMs.
2.
Restart
the
blade
server.
3.
Perform
the
system
checkout
procedure.
See
“System
checkout”
on
page
48.
If
the
problem
remains,
replace
the
system-board
assembly.
Contact
a
service
support
representative
for
assistance.
Chapter
7.
Solving
problems
73