IBM JS20 User Guide - Page 85
Setenv/$Setenv
![]() |
UPC - 000435230263
View all IBM JS20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
Table 1. Abbreviated list of firmware error codes (continued) Error code Failing device or problem found Suggested action 25A80210 Setenv/$Setenv parameter error; name contains a null character. If the problem remains, replace the battery in the blade server. For additional information, see the Hardware Maintenance and Troubleshooting Guide. Note: After you replace the battery, you must reset the system date and time through the operating system that you installed. 25A80211 Setenv/$Setenv parameter error; value contains a null character. If the problem still remains, replace the system-board assembly. Contact a service support representative for assistance. If the problem remains, replace the battery in the blade server. For additional information, see the Hardware Maintenance and Troubleshooting Guide. Note: After you replace the battery, you must reset the system date and time through the operating system that you installed. 25A80998 NVRAMRC script evaluation error. If the problem still remains, replace the system-board assembly. Contact a service support representative for assistance. Perform the following steps to remove the NVRAMRC script: 1. Boot to the open firmware prompt. 2. Enter the following command: 0 0 " nvramrc" $setenv 25A80999 NVRAMRC script evaluation error; stack unbalanced on completion. If the problem remains, contact your system administrator for assistance. This is a firmware debug environment error. No action is required. No component replacement is required. 25000000 25C00000 The blade server failed to set the Write Delay (WRDLY) bit in the memory controller register. No DIMMs were detected. If the problem remains, have the blade server serviced. 1. Start from the PERM flash image to reflash the TEMP image for recovery. See "Recovering the system firmware code" on page 84. 2. If the problem remains, replace the blade server. Contact a service support representative for assistance. Note: For additional information about DIMMs, see "Installing memory modules" on page 24. 1. Make sure that the DIMMs are correctly seated. If necessary, reseat the DIMMs. 2. Restart the blade server. 3. Perform the system checkout procedure. See "System checkout" on page 48. If the problem remains, replace the system-board assembly. Contact a service support representative for assistance. Chapter 7. Solving problems 73
![](/manual_guide/products/ibm-js20-user-guide-5dc2616/85.png)