Table 1. Abbreviated list of firmware error codes (continued) Error code Failing device or problem found Suggested action 25C0xx yy DIMM failure: where xx and yy are: xx Description 01 DIMM4 missing 02 DIMM3 unsupported and DIMM4 missing 04 DIMM3 failed and DIMM4 missing 10 DIMM3 missing 12 DIMM3 unsupported 14 DIMM3 failed 20 DIMM3 missing and DIMM4 unsupported Note: For additional information about DIMMs, see "Installing memory modules" on page 24. 1. Make sure that all the DIMMs in the blade server are supported. Replace all the unsupported DIMMs. 2. Make sure that the DIMMs are installed in matched pairs. If the DIMMs are not installed in matched pairs, reinstall them in matched pairs. 3. Make sure that the DIMMs are correctly seated. If necessary, reseat the DIMMs. 4. Restart the blade server. 5. Remove and reinstall the DIMMs one at a time until the failing DIMM is isolated. Replace the defective DIMM. If the problem remains, replace the system-board assembly. Contact a service support representative for assistance. 21 DIMM4 unsupported 22 DIMM3 and DIMM4 unsupported 24 DIMM3 failed and DIMM4 unsupported 40 DIMM3 missing and DIMM4 failed 41 DIMM4 failed 42 DIMM4 failed and DIMM3 unsupported 44 DIMM3 and DIMM4 failed 88 DIMM3 and DIMM4 mismatch 74 BladeCenter JS20 Type 8842: Installation and User's Guide