IBM x3500 User Guide - Page 30
System-board, external, connectors, Light, diagnostics, panel - cpu
UPC - 883436005760
View all IBM x3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
System-board external connectors The following illustration shows the external input/output connectors and the NMI switch on the system board. Mouse Keyboard Serial 1 (COM 1) LPT VGA USB 4 RJ45 USB 3 RJ45 NMI Serial 2 (COM 2) Light path diagnostics panel The following illustration shows the remind button and the LEDs on the light path diagnostics panel. The light path diagnostics panel is inside the server under the left-side cover and the error LEDs are also visible through the left-side cover. 1 POWER SUPPLY 2 CONFIG TEMP REMIND MEMORY DASD/ RAID FAN CPU S_ERR VRM PCI BUS SP BUS NMI SEE INSIDE COVER FOR MORE SERVICE INFORMATION Use the remind button on the light path diagnostic panel to acknowledge that an error has occurred without taking further action. When you push the remind button, the system error LED will flash every 2 seconds until the error is fixed. If another error occurs, the system error LED will then stop flashing and return to a solid on state. For more information about light path diagnostics, see the Problem Determination and Service Guide on the IBM System x Documentation CD. The following table lists the light path diagnostics LEDs, the problems that they indicate, and actions to solve the problems. 16 IBM System x3500 Type 7977: User's Guide