Intel S1200RP Service Guide - Page 56

Installing 8x3.5 Hot-swap Hard Drive Cage with Backplane

Page 56 highlights

Server Utilities 6. Use screwdriver to release the hot-swap hard drive cage (see letter A) from the chassis and remove the hot-swap hard drive cage (see letter B). Figure 66. Removing the 8x3.5" HDD Cage Installing 8x3.5" Hot-swap Hard Drive Cage with Backplane CAUTION It is critical that you connect the SAS/SATA data cables correctly from the SAS/SATA backplane to your server board or RAID controller card. Failure to do so may result in data loss. 1. Observe the safety and ESD precautions at the beginning of this manual. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the chassis cover. For instructions, see Removing the System Side Cover. 4. Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel". 5. Install the 8x3.5" Hot-Swap Hard Drive Cage. 1) Slide the 8x3.5" Hot-Swap Drive Cage into the slot (see letter A). 2) Secure the Hard Drive Cage with the Screws (see letter B). Intel® Server System P4000RP Family Service Guide 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163

Server Utilities
Intel
®
Server System P4000RP Family Service Guide
43
6.
Use screwdriver to release the hot-swap hard drive cage (see letter
A
) from the chassis and
remove the hot-swap hard drive cage (see letter
B
).
Figure 66. Removing the 8x3.5" HDD Cage
Installing 8x3.5" Hot-swap Hard Drive Cage with Backplane
CAUTION
It is critical that you connect the SAS/SATA data cables correctly from the SAS/SATA
backplane to your server board or RAID controller card. Failure to do so may result in
data loss.
1.
Observe the safety and ESD precautions at the beginning of this manual.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the chassis cover. For instructions, see
Removing the System Side Cover
.
4.
Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel”.
5.
Install the 8x3.5" Hot-Swap Hard Drive Cage.
1)
Slide the 8x3.5" Hot-Swap Drive Cage into the slot (see letter
A
).
2)
Secure the Hard Drive Cage with the Screws (see letter
B
).