Lenovo Storage N3310 (English) User Guide and Hardware Maintenance Manual - Le - Page 42
Power supply status LEDs, Connecting the cables, in the following topics
View all Lenovo Storage N3310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Power supply status LEDs Each hot-swap power supply has three status LEDs. 3 2 1 Figure 12. Power supply status LEDs LED 1 Input status LED Off Status On, green 2 Output status Off LED Blinking, green (about one flash every two seconds) Blinking, green (about two flashes each second) On, green 3 Fault LED Off On, amber Description The power supply is disconnected from the ac power source. The power supply is connected to the ac power source. The storage product is off or the power supply is not working normally. The power supply is in cold redundancy active mode. The power supply is in cold redundancy sleep mode. The storage product is on and the power supply is working normally. The power supply is working normally. The power supply has failed. Action No action is needed. No action is needed. Replace the power supply. See "Installing or replacing a hot-swap redundant power supply" on page 83. No action is needed. No action is needed. No action is needed. No action is needed. Replace the power supply. See "Installing or replacing a hot-swap redundant power supply" on page 83. Connecting the cables To connect the signal cables from the installed hardware components, refer to the related information in the following topics: • "Hot-swap-drive backplane" on page 22 • "ThinkServer RAID 710 Adapter" on page 21 • "System board components" on page 23 28 Lenovo Storage N3310 User Guide and Hardware Maintenance Manual