Table 5.7 Set Controller Properties (Cont.) Description Sets the properties on the selected controller(s). The possible settings are: CacheFlushInterval: Cache flush interval in seconds. Values: 0 to 255. RebuildRate: Rebuild rate. Values: 0 to 100. PatrolReadRate: Patrol read rate. Values: 0 to 100. BgiRate: Background initilization rate. Values: 0 to 100. CCRate: Consistency check rate. Values: 0 to 100. ReconRate: Reconstruction rate. Values: 0 to 100. SpinupDriveCount: Max number of drives to spin up at one time. Values: 0 to 255. SpinupDelay: Number of seconds to delay among spinup groups. Values: 0 to 255. CoercionMode: Drive capacity Coercion mode. Values: 0 - None, 1 - 128 Mbytes, 2 - 1 Gbytes. ClusterEnable: Cluster is enabled or disabled. Values: 0 - Disabled, 1 - Enabled. PredFailPollInterval: Number of seconds between predicted fail polls. Values: 0 to 65535. BatWarnDsbl: Disable warnings for missing battery or missing hardware. Values: 0 - Enabled, 1 - Disabled. EccBucketSize: Size of ECC single-bit-error bucket. Values: 0 to 255. EccBucketLeakRate: Leak rate (in minutes) of ECC single-bit-error bucket. Values: 0 to 65535. AbortCCOnError: AlarmEnbl: Set alarm to Enabled. AlarmDsbl: Set alarm to Disabled. AlarmSilence: Silence an active alarm. SMARTCpyBkEnbl: Enable copyback operation on Self-Monitoring Analysis and Reporting Technology (SMART) errors. Copyback is initiated when the first SMART error occurs on a drive that is part of a virtual drive. AutoDetectBackPlaneDsbl: Detect automatically if the backplane has been disabled. CopyBackDsbl: Disable or enable the copyback operation. LoadBalanceMode: Disable or enable the load balancing mode. NCQEnbl: Enable the native command queueing. NCQDsbl: Disable the native command queueing. SSDSMARTCpyBkEnbl: Enable copyback operation on Self-Monitoring Analysis and Reporting Technology (SMART) errors on a Solid State Drive (SSD). Copyback is initiated when the first SMART error occurs on a SSD that is part of a virtual drive. MaintainPdFailHistoryEnbl: Enable maintenance of the history of a failed drive. EnblSpinDownUnConfigDrvs: Enable spindown of unconfigured drives. EnblSSDPatrolRead: Enable the patrol read operation (media scan) on a SSD. AutoEnhancedImportEnbl: Enable the automatic enhanced import of foreign drives. AutoEnhancedImportDsbl: Disable the automatic enhanced import of foreign drives. UseFDEOnlyEncrypt: Use encryption on FDE drives only. PrCorrectUncfgdAreas: 5.4.6 Display Specified Controller Properties Use the command in Table 5.8 to display specified properties on the selected controller(s). Controller Property-Related Options 5-9