Oki GL408e GL408e/GL412e User's Guide - Page 110

Imperial, Metric, Transparent, Opaque, Report, Standard, S-462, Process, Ignore

Page 110 highlights

MENU Units of Measure Imperial* Row Offset 00.00 Inch* Column Offset 00.00 Inch* Format Attrib. XOR* Error Handling Off* Vert. DPI Adjust 0* Compatibility Standard* Length Cmd (STXc) Process* Unit 4: Printer Configuration DGL EMULATION MODE (TABLE 4-12) DESCRIPTION Selects how the printer will interpret measurements. • Imperial - factory default. American Standard values. • Metric - uses Metric values. Note: n and m commands override this setting and will stay in effect until the printer is taken offline, then returned online. Shifts the vertical start of the print position. This a the user setting for row adjustment. The allowable range is 0 to 99.99 inches or 999.9 millimeters. The factory default is 0. Note: The Label Formatting command (R) only temporarily overrides this setting; it reverts back to this setting after the current label format is finished. Shifts the horizontal, left-justified start posiotn to the right without shifting the Label Width termination point to the right. This a the user setting for row adjustment. The allowable range is 0 to 99.99 inches or 999.9 millimeters. The factory default is 0. Note: The Label Formatting command (C) only temporarily overrides this setting; it reverts back to this setting after the current label format is finished. Format Attribute. Affects the manner in which overlapping text and graphics are treated as the label is printed. • XOR - factory default. Intersecting text strings, images, and barcodes print on top of one another. • Transparent - intersecting text strings, images, and barcodes will not be printed. An odd quantity of overlapping objects will print. • Opaque - intersecting text strings, images, and barcodes are obliterated by those last formatted. Each character cell is treated as opaque. Defines how the emulation handles errors detected in the data stream. For all selections, data processing will not be aborted when errors are detected and labels will be printed as best possible. Commands containing errors will be ignored. • Off - factory default. Without signals to the user when errors are detected. • Report - the printer will beep when one or more errors are detected and the first command that contains an error is displayed on the printer's LCD in mnemonic form. • Beep - the printer will beep once if one or more errors are detected. This option fine adjusts the resolution used to scale the page elements/coordinates. In cases where the printed label length is incorrect, the vertical resolution value DGL uses for calculations can be fine adjusted by this menu. Negative values result in a lower DPI value and thus a longer label. Positive values result in a higher DPI value, and thus a shorter label. The allowable range is -100 to +100, with a factory default of 0. Determines compatibility with legacy Datamax emulations. • Standard - factory default. Standard emulation. • S-462 - specific printer model. Allows the user to disable the Length Command. • Process - factory default. Acknowledges length commands. • Ignore - does not acknowledge length commands. GL408-412e Operator Manual 4-74 PN: 9001163A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

Unit 4:
Printer Configuration
GL408-412e Operator Manual
4-74
PN: 9001163A
Selects how the printer will interpret measurements.
Imperial
- factory default. American Standard values.
Metric
- uses Metric values.
Note: <STX>n and <STX>m commands override this setting and will stay in effect until the printer
is taken offline, then returned online.
Shifts the vertical start of the print position. This a the user setting for row adjustment.
The allowable range is
0
to
99.99
inches or
999.9
millimeters. The factory default is
0
.
Note: The Label Formatting command (R) only temporarily overrides this setting; it reverts back
to this setting after the current label format is finished.
Shifts the horizontal, left-justified start posiotn to the right without shifting the Label Width
termination point to the right. This a the user setting for row adjustment.
The allowable range is
0
to
99.99
inches or
999.9
millimeters. The factory default is
0
.
Note: The Label Formatting command (C) only temporarily overrides this setting; it reverts back
to this setting after the current label format is finished.
Format Attribute. Affects the manner in which overlapping text and graphics are treated as the
label is printed.
XOR
- factory default. Intersecting text strings, images, and barcodes print on top of one
another.
Transparent
- intersecting text strings, images, and barcodes will not be printed. An odd
quantity of overlapping objects will print.
Opaque
- intersecting text strings, images, and barcodes are obliterated by those last
formatted. Each character cell is treated as opaque.
Defines how the emulation handles errors detected in the data stream. For all selections, data
processing will not be aborted when errors are detected and labels will be printed as best
possible. Commands containing errors will be ignored.
Off
- factory default. Without signals to the user when errors are detected.
Report
- the printer will beep when one or more errors are detected and the first command
that contains an error is displayed on the printer’s LCD in mnemonic form.
Beep
- the printer will beep once if one or more errors are detected.
This option fine adjusts the resolution used to scale the page elements/coordinates. In cases
where the printed label length is incorrect, the vertical resolution value DGL uses for calculations
can be fine adjusted by this menu.
Negative values result in a lower DPI value and thus a longer label. Positive values result in a
higher DPI value, and thus a shorter label.
The allowable range is
-100
to
+100
, with a factory default of
0
.
Determines compatibility with legacy Datamax emulations.
Standard
- factory default. Standard emulation.
S-462
- specific printer model.
Allows the user to disable the Length Command.
Process
- factory default. Acknowledges length commands.
Ignore
- does not acknowledge length commands.
DGL EMULATION MODE (TABLE 4-12)
MENU
DESCRIPTION
Units of Measure
Imperial*
Row Offset
00.00
Inch*
Column Offset
00.00
Inch*
Format Attrib.
XOR*
Error Handling
Off*
Vert. DPI Adjust
0*
Compatibility
Standard*
Length Cmd (STXc)
Process*