Oki GL408e GL408e/GL412e User's Guide - Page 80

Parallel Interface Mode Table 4-5, Description, Disable, Enable, Enq/stx

Page 80 highlights

MENU Poll Response 0 ms* Idle Response Disable* One Char Enquiry Disable* Printer Status Disable* Framing Errors Enable* MENU INTERFACES Unit 4: Printer Configuration SERIAL INTERFACE MODE (TABLE 4-4) DESCRIPTION This option is for the Series1 protocol. After receiving a poll character, the printer will wait the poll response time in milliseconds before sending the response. The allowable range is 0 to 30 ms, and the factory default is 0 ms. This option is for the Series1 protocol. • Disable - factory default. • Enable - the printer sends a response character every two seconds while the quanity of valid bytes in the buffer is less than 75 percent of the buffer size. One Character Enquiry. This mode uses the poll character to detect a request from the host and sends a response back to the host. • Disable - factory default. Poll character will not detect. • Enable - poll character will detect. If enabled, allows the printer to respond according to two different response tables when an ENQ command is sent to the printer. • Disable - factory default. A response is not sent. • ENQ/STX - when the printer receives an ENQ, the printer responds with a status according to ENQ/STX parameters. • ENQ - when the printer receives an ENQ, the printer responds with a status according to ENQ parameters. These are possible errors that can occur when serial interface settings of the printer do not match those of the host computer. • Enable - factory default. If a framing error occurs, a fault message will display on the operator panel. • Disable - if a framing error occurs, a fault message will not display on the operator panel. PARALLEL INTERFACE MODE (TABLE 4-5) DESCRIPTION Permits entry into the INTERFACES Mode. INTERFACES Ignore CR/LF Item No. Check BCC Check History Buffer Comm. Protocol Host Interface Parallel Port USB Port Serial Port Printer Mgmt Is the menu selection screen for the INTERFACES Mode. GL408-412e Operator Manual 4-44 PN: 9001163A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

Unit 4:
Printer Configuration
GL408-412e Operator Manual
4-44
PN: 9001163A
This option is for the Series1 protocol. After receiving a poll character, the printer will wait the poll
response time in milliseconds before sending the response.
The allowable range is
0
to
30 ms
, and the factory default is
0 ms
.
This option is for the Series1 protocol.
Disable
- factory default.
Enable
- the printer sends a response character every two seconds while the quanity of valid
bytes in the buffer is less than 75 percent of the buffer size.
One Character Enquiry. This mode uses the poll character to detect a request from the host and
sends a response back to the host.
Disable
- factory default. Poll character will not detect.
Enable
- poll character will detect.
If enabled, allows the printer to respond according to two different response tables when an ENQ
command is sent to the printer.
Disable
- factory default. A response is not sent.
ENQ/STX
- when the printer receives an ENQ, the printer responds with a status according
to ENQ/STX parameters.
ENQ
- when the printer receives an ENQ, the printer responds with a status according to
ENQ parameters.
These are possible errors that can occur when serial interface settings of the printer do not match
those of the host computer.
Enable
- factory default. If a framing error occurs, a fault message will display on the
operator panel.
Disable
- if a framing error occurs, a fault message will not display on the operator panel.
PARALLEL INTERFACE MODE (TABLE 4-5)
MENU
DESCRIPTION
Permits entry into the INTERFACES Mode.
Is the menu selection screen for the INTERFACES Mode.
SERIAL INTERFACE MODE (TABLE 4-4)
MENU
DESCRIPTION
Poll Response
0
ms*
Idle Response
Disable*
One Char Enquiry
Disable*
Printer Status
Disable*
Framing Errors
Enable*
INTERFACES
INTERFACES
Ignore CR/LF
Item No. Check
BCC Check
History Buffer
Comm. Protocol
Host Interface
Parallel Port
USB Port
Serial Port
Printer Mgmt