Oki GL408e GL408e/GL412e User's Guide - Page 113

Auto Select, <ESC><LF><NUL&gt, User Defined, SFCC Separator, SFCC Terminator, Process

Page 113 highlights

Unit 4: Printer Configuration MENU SFCC Select Auto Select* EURO Symbol 0xB0* TGL EMULATION MODE (TABLE 4-13) DESCRIPTION Special Function Control Code. These codes are specific to the delimiters of separate print jobs and commands. They can be customized and therefore changed via this menu so the printer can recognize these alternate control characters. • Auto Select - factory default. The printer selects the SFCC set based upon the received host data. • - is a predefined set. The ESC character is the SFCC, the LF is the SFCC-Separator, and the NULL character is the SFCC-Terminator. • { I } - is a predefined set. The { character is the SFCC, the I is the SFCC-Separator, and the } is the SFCC-Terminator. • User Defined - if this option is selected, three additional menus appear. These menus allow the SFCC, SFCC-Separator, and SFCC-Terminator to be individually configured. • SFCC - can set value between 0x0 and 0xFF. The factory default is 0x7B. • SFCC Separator - can set value between 0x0 and 0xFF. The factory default is 0x7C. • SFCC Terminator - can set value between 0x0 and 0xFF. The factory default is 0x7D. This menu allows the position of the EURO symbol in the cold pages to be configured. The EURO symbol can be set to any value between 0x20 and 0xFF. The factory default is 0xB0. Speed CMDs Process* AY Intensity CMD Process* U1/U2 Move CMDs Process* XS Sensor Param Process* XS Media 'C' Act Continuous* Speed Commands. Determines if engine commands that affect the print/feed speed will be processed or ignored. To adjust the print/feed speed through the operator panel, use this menu to prevent the host commands from overriding these settings. When Ignore is selected, the TGL ignores the following comands or command parameters: • The print speed parameter in the XS command. The parameter will not have an effect; the Print Speed value as configured in the Media Control menu will be used. • The feed speed parameter in the T command. The parameter will not have an effect; the Slew Speed value as configured in the Media Control menu will be used. The factory default is Process. Allows the selection of how the printer will respond to print intensity (darkness) commands. • Process - factory default. Sent commands from the host take precedence. • Ignore - printer settings take precedence. Allows the selection of how the printer will respond to commands to move paper forward (U1) or backward (U2). • Process - factory default. Sent commands from the host take precedence. • Ignore - printer settings take precedence. The paper will not be moved when either command is received. XS Sensor Parameter. Allows the selection of how the printer will respond to the XS command setting the sensor type parameters. • Process - factory default. Sent commands from the host take precedence. • Ignore - printer settings take precedence. The paper will not be moved when either command is received. TGL will use the sensor type as configured through Gap/Mark Sensor under the Calibrate CTRL menu. Defines which media mode TGL will operate on receipt of a 'C' (strip mode) from the issue mode parameter in the XS command. Any of the supported media modes can be selected. • Continuous - factory default. Sent commands from the host take precedence. • Ignore - will use the issue mode as configured through Media Handling under the Media Control menu. GL408-412e Operator Manual 4-77 PN: 9001163A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

Unit 4:
Printer Configuration
GL408-412e Operator Manual
4-77
PN: 9001163A
Special Function Control Code. These codes are specific to the delimiters of separate print jobs
and commands. They can be customized and therefore changed via this menu so the printer can
recognize these alternate control characters.
Auto Select
- factory default. The printer selects the SFCC set based upon the received host
data.
<ESC><LF><NUL>
- is a predefined set. The ESC character is the SFCC, the LF is the
SFCC-Separator, and the NULL character is the SFCC-Terminator.
{ I }
- is a predefined set. The { character is the SFCC, the I is the SFCC-Separator, and the }
is the SFCC-Terminator.
User Defined
- if this option is selected, three additional menus appear. These menus allow
the SFCC, SFCC-Separator, and SFCC-Terminator to be individually configured.
SFCC
- can set value between 0x0 and 0xFF. The factory default is 0x7B.
SFCC Separator
- can set value between 0x0 and 0xFF. The factory default is 0x7C.
SFCC Terminator
- can set value between 0x0 and 0xFF. The factory default is 0x7D.
This menu allows the position of the EURO symbol in the cold pages to be configured. The
EURO symbol can be set to any value between
0x20
and
0xFF
.
The factory default is
0xB0
.
Speed Commands. Determines if engine commands that affect the print/feed speed will be
processed or ignored. To adjust the print/feed speed through the operator panel, use this menu to
prevent the host commands from overriding these settings. When Ignore is selected, the TGL
ignores the following comands or command parameters:
The print speed parameter in the XS command. The parameter will not have an effect; the
Print Speed value as configured in the Media Control menu will be used.
The feed speed parameter in the T command. The parameter will not have an effect; the
Slew Speed value as configured in the Media Control menu will be used.
The factory default is
Process
.
Allows the selection of how the printer will respond to print intensity (darkness) commands.
Process
- factory default. Sent commands from the host take precedence.
Ignore
- printer settings take precedence.
Allows the selection of how the printer will respond to commands to move paper forward (U1) or
backward (U2).
Process
- factory default. Sent commands from the host take precedence.
Ignore
- printer settings take precedence. The paper will not be moved when either
command is received.
XS Sensor Parameter. Allows the selection of how the printer will respond to the XS command
setting the sensor type parameters.
Process
- factory default. Sent commands from the host take precedence.
Ignore
- printer settings take precedence. The paper will not be moved when either
command is received. TGL will use the sensor type as configured through Gap/Mark Sensor
under the Calibrate CTRL menu.
Defines which media mode TGL will operate on receipt of a ‘C’ (strip mode) from the issue mode
parameter in the XS command. Any of the supported media modes can be selected.
Continuous
- factory default. Sent commands from the host take precedence.
Ignore
- will use the issue mode as configured through Media Handling under the Media
Control menu.
TGL EMULATION MODE (TABLE 4-13)
MENU
DESCRIPTION
SFCC Select
Auto Select*
EURO Symbol
0xB0*
Speed CMDs
Process*
AY Intensity CMD
Process*
U1/U2 Move CMDs
Process*
XS Sensor Param
Process*
XS Media ‘C’ Act
Continuous*