Sanyo PLC-HF15000L RS232 Expand - Page 25

CF_GAMMA Command, 4.13 CF_NZRED Command, 4.14 CF_PROGV Command

Page 25 highlights

PLC-HF15000L Expand Serial Command Functional Specifications 8.4.12 CF_GAMMA Command Command "CF_GAMMA_%1" [CR] "000-015 Directly specify setting value of Gamma %1 "UP Increment setting value of Gamma by 1 "DN Decrement setting value of Gamma by 1 Details Set user controlled value of Gamma. (Available only in the normal Power ON status) The value set by this command is not stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.4.13 CF_NZRED Command Command "CF_NZRED_%1" [CR] %1 "ON Set Noise Reduction to ON "OFF Set Noise Reduction to OFF Details Set or Cancel Noise Reduction. (Available only in the normal Power ON status) The value set by this command is not stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable Response Unacceptable "000" [CR] "Error Code" [CR] 8.4.14 CF_PROGV Command Command "CF_PROGV_%1" [CR] "ON Set Progressive scan to ON %1 "FILM Set Progressive scan to Film mode "OFF Set Progressive scan to OFF Details Set or Cancel Progressive scan. (Valid only when it is in the normal Power ON status.) The value set by this command is not stored in the projector's memory. Therefore, when the power is turned to ALL OFF status, the value returns to the original setting. (It is stored in Suspend mode.) Acceptable Response Unacceptable "000" [CR] "Error Code" [CR] 25/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF15000L
Expand Serial Command Functional Specifications
25/105
8.4.12 CF_GAMMA Command
Command
“CF_GAMMA_%1” [CR]
%1
“000-015” ---------------- Directly specify setting value of Gamma
“UP”---------------------- Increment setting value of Gamma by 1
“DN”---------------------- Decrement setting value of Gamma by 1
Details
Set user controlled value of Gamma. (Available only in the normal Power ON
status)
The value set by this command is not stored in the projector’s memory. Therefore,
when the power is turned to ALL OFF status, the value returns to the original
setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.4.13 CF_NZRED Command
Command
“CF_NZRED_%1” [CR]
%1
“ON” ------------------------------Set Noise Reduction to ON
“OFF” ---------------------------- Set Noise Reduction to OFF
Details
Set or Cancel Noise Reduction. (Available only in the normal Power ON status)
The value set by this command is not stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.4.14 CF_PROGV Command
Command
“CF_PROGV_%1” [CR]
%1
“ON” ------------------------------ Set Progressive scan to ON
“FILM” ---------------------------- Set Progressive scan to Film mode
“OFF” ---------------------------- Set Progressive scan to OFF
Details
Set or Cancel Progressive scan. (Valid only when it is in the normal Power ON
status.)
The value set by this command is not stored in the projector’s memory. Therefore,
when the power is turned to ALL OFF status, the value returns to the original
setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]