Sanyo PLC-HF15000L RS232 Expand - Page 59

CF_CCAPTIONCOLOR Command, 9.59 CF_FILH Command, 9.60 CF_FILTIMER Command, 9.61 CF_FILCLEANTIMER

Page 59 highlights

PLC-HF15000L Expand Serial Command Functional Specifications 8.9.58 CF_CCAPTIONCOLOR Command Command "CF_CCAPTIONCOLOR _%1" [CR] %1 "COLOR" ------- Select Color "WHITE" -------- Select White Details Select color of Closed caption. The status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF. This command is available in normal Power ON status. Note) Closed caption is available under conditions below; Entered signal is appropriate (NTSC signal from Video or S-video) or System is fixed to NTSC. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.59 CF_FILH Command Command "CF_FILH_%1" [CR] %1 "RST Reset Filter used time Details Reset used time for filter of projector Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.60 CF_FILTIMER Command Command "CF_FILTIMER_%1" [CR] "04000 Set 4000 hours (for automatic cleaning filter) "08000 Set 8000 hours (for automatic cleaning filter) "12000 Set 12000 hours (for automatic cleaning filter) "16000 Set 16000 hours (for automatic cleaning filter) "00010 Set 10 hours (for a smoke proof filter) %1 "00015 Set 15 hours (for a smoke proof filter) "00020 Set 20 hours (for a smoke proof filter) *When the parameter does not meet the type of filter, error code "101" is returned and the command is not executed. EX) When %1=00010 is received while the automatic cleaning filter is mounted, error code "101" is returned. "OFF Set Off (Do not warning display) Details Set time to display Filter cleaning / replacement warning on screen Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.61 CF_FILCLEANTIMER Command Command "CF_FILCLEANTIMER_%1" [CR] "050 Set 50 hours "100 Set 100 hours %1 "150 Set 150 hours "UP The same operation as pressing Up key or Left key "DN The same operation as pressing Down key or Right key Details Set the time of Auto cleaning timer. (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status. Acceptable "000" [CR] Response Unacceptable "Error Code" [CR] 59/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF15000L
Expand Serial Command Functional Specifications
59/105
8.9.58 CF_CCAPTIONCOLOR Command
Command
“CF_CCAPTIONCOLOR _%1” [CR]
%1
“COLOR” ------- Select Color
“WHITE” -------- Select White
Details
Select color of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF. This command is available in normal Power ON status.
Note) Closed caption is available under conditions below;
Entered signal is appropriate (NTSC signal from Video or S-video) or System is
fixed to NTSC.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.59 CF_FILH Command
Command
“CF_FILH_%1” [CR]
%1
“RST” ---------------------- Reset Filter used time
Details
Reset used time for filter of projector
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.60 CF_FILTIMER Command
Command
“CF_FILTIMER_%1” [CR]
%1
“04000” ---------------------- Set 4000 hours (for automatic cleaning filter)
“08000” ---------------------- Set 8000 hours (for automatic cleaning filter)
“12000” ---------------------- Set 12000 hours (for automatic cleaning filter)
“16000” ---------------------- Set 16000 hours (for automatic cleaning filter)
“00010” ---------------------- Set 10 hours (for a smoke proof filter)
“00015” ---------------------- Set 15 hours (for a smoke proof filter)
“00020” ---------------------- Set 20 hours (for a smoke proof filter)
*When the parameter does not meet the type of filter, error code “101” is
returned and the command is not executed.
EX) When %1=00010 is received while the automatic cleaning filter is
mounted, error code “101” is returned.
“OFF” ---------------------- Set Off (Do not warning display)
Details
Set time to display Filter cleaning / replacement warning on screen
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.61 CF_FILCLEANTIMER Command
Command
“CF_FILCLEANTIMER_%1” [CR]
%1
“050” ---------------------- Set 50 hours
“100” ---------------------- Set 100 hours
“150” ---------------------- Set 150 hours
“UP” ----------- The same operation as pressing Up key or Left key
“DN” -----------The same operation as pressing Down key or Right key
Details
Set the time of Auto cleaning timer.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]