Sanyo PLC-HF15000L RS232 Expand - Page 65
Image Status Read Commands, 4.1 CR_CONT Command, 4.2 CR_BRIGHT Command, 4.3 CR_COLOR Command, 4.4
View all Sanyo PLC-HF15000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
PLC-HF15000L Expand Serial Command Functional Specifications 9.4 Image Status Read Commands 9.4.1 CR_CONT Command Command "CR_CONT" [CR] Details Get user controlled value of Contrast Acceptable Response %1 "000_%1" [CR] "000" - "063" Unacceptable "?" [CR] 9.4.2 CR_BRIGHT Command Command "CR_BRIGHT" [CR] Details Get user controlled value of Brightness Acceptable Response %1 "000_%1" [CR] "000" - "063" Unacceptable "?" [CR] 9.4.3 CR_COLOR Command Command "CR_COLOR" [CR] Details Get user controlled value of Color Acceptable "000_%1" [CR] Response %1 Unacceptable "000" - "063" "Error Code" [CR When command is invalid in the given condition (such as being selected input) "?" [CR] --------- When unknown command is received 9.4.4 CR_TINT Command Command "CR_TINT" CR] Details Get user controlled value of Tint Acceptable "000_%1" [CR] Response %1 Unacceptable "000" - "063" "Error Code" [CR When command is invalid in the given condition (such as being selected input) "?" [CR] --------- When unknown command is received 9.4.5 CR_APCTRL Command Command "CR_APCTRL" [CR] Details Get setting status of Auto Picture Control Acceptable "000_%1" [CR] "L1 Operate Auto Picture Control with Level1 Response %1 "L2 Operate Auto Picture Control with Level2 "OFF Set Auto Picture Control OFF Unacceptable "?" [CR] 65/105