Sanyo PLC-HF15000L RS232 Expand - Page 83

Lamp Status Read Commands, 9.1 CR_LAMPREPL Command, 9.2 CR_LAMPMODE Command, 9.3 CR_LAMPCONSTTAR

Page 83 highlights

PLC-HF15000L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Commands 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL" [CR] Details Get the information of Lamp Replacement time Acceptable "000_%1" [CR] "4****" 4 indicates 4 lamps are used in this model. indicates the status of each lamp in lamp number order. "Y" means the lamp operating time is over the Response %1 threshold for lamp replacement, and "N" means it has not reached to. e.g. "4NYYN" --------- This indicates it is 4-lamps system, and Lamp #1 and #4 have not been reached to the replacement time while #2 and #3 should be replaced. Unacceptable "?" [CR] 9.9.2 CR_LAMPMODE Command Command "CR_LAMPMODE" [CR] Details Get Lamp mode setting status Acceptable "000_%1" [CR] "4LAMP Lamp mode is set to 4-Lamps "3LAMPAUTO" --- Lamp mode is set to 3-Lamps (Auto) and automatically and preferentially uses lamps with shorter cumulated lighting time "3LAMP123" ----- Lamp mode is set to 3-Lamps (LAMP1, 2 and 3) "3LAMP234" ----- Lamp mode is set to 3-Lamps (LAMP2, 3 and 4) Response %1 "3LAMP134" ----- Lamp mode is set to 3-Lamps (LAMP1, 3 and 4) "3LAMP124" ----- Lamp mode is set to 3-Lamps (LAMP1, 2 and 4) "2LAMPAUTO" --- Lamp mode is set to 2-Lamps (Auto) and automatically and preferentially uses lamps with shorter cumulated lighting time "2LAMP23" ----- Lamp mode is set to 2-Lamps (LAMP2 and 3) "2LAMP14" ----- Lamp mode is set to 2-Lamps (LAMP1 and 4) "CONSTANT" ------ Lamp mode is set to Constant mode. Unacceptable "Error Code" [CR] 9.9.3 CR_LAMPCONSTTAR Command Command "CR_LAMPCONSTTAR" [CR] Details Get value of Target for Constant mode Acceptable "000_%1" [CR] Response %1 "0000"-"1024" Unacceptable "Error Code" [CR] 9.9.4 CR_LAMPCONSTCUR Command Command "CR_LAMPCONSTCUR" [CR] Details Get value of Current for Constant mode Acceptable Response %1 "000_%1" [CR] "0000"-"1024" Unacceptable "Error Code" [CR] 83/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF15000L
Expand Serial Command Functional Specifications
83/105
9.9 Lamp Status Read Commands
9.9.1 CR_LAMPREPL Command
Command
“CR_LAMPREPL” [CR]
Details
Get the information of Lamp Replacement time
Acceptable
“000_%1” [CR]
%1
“4****”
4 ---------------- indicates 4 lamps are used in this model.
* ---------------- indicates the status of each lamp in lamp number
order.
“Y” means the lamp operating time is over the
threshold for lamp replacement, and “N” means
it has not reached to.
e.g.
“4NYYN” --------- This indicates it is 4-lamps system, and Lamp #1
and
#4
have
not
been
reached
to
the
replacement time while #2 and #3 should be
replaced.
Response
Unacceptable
“?” [CR]
9.9.2 CR_LAMPMODE Command
Command
“CR_LAMPMODE” [CR]
Details
Get Lamp mode setting status
Acceptable
“000_%1” [CR]
%1
“4LAMP” ------------- Lamp mode is set to 4-Lamps
“3LAMPAUTO” --- Lamp mode is set to 3-Lamps (Auto) and
automatically and preferentially uses lamps
with shorter cumulated lighting time
“3LAMP123” ----- Lamp mode is set to 3-Lamps (LAMP1, 2 and 3)
“3LAMP234” ----- Lamp mode is set to 3-Lamps (LAMP2, 3 and 4)
“3LAMP134” ----- Lamp mode is set to 3-Lamps (LAMP1, 3 and 4)
“3LAMP124” ----- Lamp mode is set to 3-Lamps (LAMP1, 2 and 4)
“2LAMPAUTO” --- Lamp mode is set to 2-Lamps (Auto) and
automatically and preferentially uses lamps
with shorter cumulated lighting time
“2LAMP23” ----- Lamp mode is set to 2-Lamps (LAMP2 and 3)
“2LAMP14” ----- Lamp mode is set to 2-Lamps (LAMP1 and 4)
“CONSTANT” ------ Lamp mode is set to Constant mode.
Response
Unacceptable
“Error Code” [CR]
9.9.3 CR_LAMPCONSTTAR Command
Command
“CR_LAMPCONSTTAR” [CR]
Details
Get value of Target for Constant mode
Acceptable
“000_%1” [CR]
%1
“0000”-“1024”
Response
Unacceptable
“Error Code” [CR]
9.9.4 CR_LAMPCONSTCUR Command
Command
“CR_LAMPCONSTCUR” [CR]
Details
Get value of Current for Constant mode
Acceptable
“000_%1” [CR]
%1
“0000”-“1024”
Response
Unacceptable
“Error Code” [CR]