Sanyo PLC-HF15000L RS232 Expand - Page 77
CR_SRCINP3 Command, 7.9 CR_SRCINP4 Command, 7.10 CR_HMSLOT Command, 7.11 CR_NMSLOT1 Command, 7. - hd
View all Sanyo PLC-HF15000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
PLC-HF15000L Expand Serial Command Functional Specifications 9.7.8 CR_SRCINP3 Command Command "CR_SRCINP3" [CR] Details Get Source of Input 3 Acceptable Response %1 "000_%1" [CR] The same data as CF_SRCINP1 Unacceptable "?" [CR] 9.7.9 CR_SRCINP4 Command Command "CR_SRCINP3" [CR] Details Get Source of Input 4 Acceptable Response %1 "000_%1" [CR] The same data as CF_SRCINP1 Unacceptable "?" [CR] 9.7.10 CR_HMSLOT Command Command "CR_HMSLOT" [CR] Details Get the total number of Slots(Inputs) Acceptable "000_%1" [CR] Response %1 "004" Unacceptable "?" [CR] 9.7.11 CR_NMSLOT1 Command Command "CR_NMSLOT1" [CR] Details Get the board name inserted to Slot1 Acceptable "000_%1" [CR] "RGB-HDMI Input1/ New RGB & HDMI board "5BNC-VIDEO Input2/ New Video board Response %1 "HDCP-DVI2 New HDCP & DVI board "DUAL-SDI HD&SD-SDI board "DUALLINK-SDI Dual-Link SDI board "NOTERMINAL There is no board inserted Unacceptable "?" [CR] 9.7.12 CR_NMSLOT2 Command Command "CR_NMSLOT2" [CR] Details Get the board name inserted to Slot 2 Acceptable Response %1 "000_%1" [CR] The same data as CR_NMSLOT1 Unacceptable "?" [CR] 77/105