Sanyo PLC-HF15000L RS232 Expand - Page 60

CF_ PTIMEMODE Command, 9.63 CF_PTIMER Command, 9.64 CF_PTIME Command, 9.65 CF_TESTPAT Command

Page 60 highlights

PLC-HF15000L Expand Serial Command Functional Specifications 8.9.62 CF_ PTIMEMODE Command Command "CF_PTIMEMODE_%1" [CR] %1 "COUNTUP Set P-timer to Count up mode "COUNTDN Set P-timer to Count down mode Details Select count up/down mode of P-timer. (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.63 CF_PTIMER Command Command "CF_PTIMER_%1" [CR] "START Start P-timer "STOP Stop P-timer %1 "RESTART Resume P-timer "RST Reset P-timer "EXIT Exit P-timer function Details Select the status of P-timer. (Available only in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.64 CF_PTIME Command Command "CF_PTIME_%1" [CR] %1 "001" - "180 Directly specify setting time Details Set the time for Count down mode of P-timer. (Available only in the normal Power ON status) The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.65 CF_TESTPAT Command Command "CF_TESTPAT_%1" [CR] "COLOR Display Color bar "GRAD1 Display 16step(white→black) "GRAD2 Display 16step(white←black) "GRAD3 Display 16step(white↓black) %1 "GRAD4 Display 16step(white↑black) "WHITE Display all white "BLACK Display all black "CROSS Display Cross "OFF Do not show test pattern display Details Execute test pattern display.(Available only in the normal Power ON status) Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 60/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF15000L
Expand Serial Command Functional Specifications
60/105
8.9.62 CF_ PTIMEMODE Command
Command
“CF_PTIMEMODE_%1” [CR]
%1
“COUNTUP” ---------------------- Set P-timer to Count up mode
“COUNTDN” ---------------------- Set P-timer to Count down mode
Details
Select count up/down mode of P-timer.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.63 CF_PTIMER Command
Command
“CF_PTIMER_%1” [CR]
%1
“START” -------------------------- Start P-timer
“STOP” ---------------------------- Stop P-timer
“RESTART” ---------------------- Resume P-timer
“RST” ------------------------------ Reset P-timer
“EXIT” ----------------------------- Exit P-timer function
Details
Select the status of P-timer.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.64 CF_PTIME Command
Command
“CF_PTIME_%1” [CR]
%1
“001” – “180” -------------------------- Directly specify setting time
Details
Set the time for Count down mode of P-timer.
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.65 CF_TESTPAT Command
Command
“CF_TESTPAT_%1” [CR]
%1
“COLOR” ---------------------- Display Color bar
“GRAD1” ---------------------- Display 16step(white
black)
“GRAD2” ---------------------- Display 16step(white
black)
“GRAD3” ---------------------- Display 16step(white
black)
“GRAD4” ---------------------- Display 16step(white
black)
“WHITE” ---------------------- Display all white
“BLACK” ---------------------- Display all black
“CROSS” --------------------- Display Cross
“OFF” ---------------------------Do not show test pattern display
Details
Execute test pattern display.(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]