Sanyo PLC-HF15000L RS232 Expand - Page 43

Setting Command, 9.1 CF_LANG Command, 9.2 CF_ MENUPOSITION Command, 9.3 CF_MENUSIZE Command

Page 43 highlights

PLC-HF15000L Expand Serial Command Functional Specifications 8.9 Setting Command 8.9.1 CF_LANG Command Command "CF_LANG_%1" [CR] "ENG Select ENGLISH "DEU Select German "FRA Select French "ITA Select Italian "ESP Select Spanish %1 "POR Select Portuguese "NED Select Dutch "SVE Select Swedish "JPN Select Japanese "CHI Select Chinese "KOR Select Korean "RUS Select Russian Details Select language for OSD. (Valid only when in the normal Power ON status.) The language set by this command is stored in EEPROM and the setting remains effective after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.2 CF_ MENUPOSITION Command Command "CF_MENUPOSITION_%1" [CR] "UP Move Menu position to upper side. %1 "DN Move Menu position to lower side. "LEFT Move Menu position to left side. "RIGHT Move Menu position to right side. Details Move Menu position. (Valid only when in the normal Power ON status.) This function is worked from the first reception of Command. * When setting beyond the area of movement is carried out, return "101" [CR] and the command is not executed. Ex.) When movement to right side has already reached limit; and "RIGHT" is received. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 8.9.3 CF_MENUSIZE Command Command "CF_MENUSIZE_%1" [CR] %1 "NORMAL Select Menu size to Normal. "DOUBLE Select Menu size to Double. Details Select Menu size. (Valid only when in the normal Power ON status.) The status set by this command is stored in EEPROM and the setting remains even after the power is turned to ALL OFF status. Acceptable Response "000" [CR] Unacceptable "Error Code" [CR] 43/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF15000L
Expand Serial Command Functional Specifications
43/105
8.9 Setting Command
8.9.1 CF_LANG Command
Command
“CF_LANG_%1” [CR]
%1
“ENG” --------------------------- Select ENGLISH
“DEU” --------------------------- Select German
“FRA” --------------------------- Select French
“ITA” ----------------------------- Select Italian
“ESP” ---------------------------- Select Spanish
“POR” --------------------------- Select Portuguese
“NED” --------------------------- Select Dutch
“SVE” --------------------------- Select Swedish
“JPN” --------------------------- Select Japanese
“CHI” ---------------------------- Select Chinese
“KOR” --------------------------- Select Korean
“RUS” --------------------------- Select Russian
Details
Select language for OSD. (Valid only when in the normal Power ON status.)
The language set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.2 CF_ MENUPOSITION Command
Command
“CF_MENUPOSITION_%1” [CR]
%1
“UP” ----------------------------- Move Menu position to upper side.
“DN” ----------------------------- Move Menu position to lower side.
“LEFT” -------------------------- Move Menu position to left side.
“RIGHT” ------------------------ Move Menu position to right side.
Details
Move Menu position. (Valid only when in the normal Power ON status.)
This function is worked from the first reception of Command.
*
When setting beyond the area of movement is carried out, return “101” [CR] and
the command is not executed.
Ex.) When movement to right side has already reached limit; and "RIGHT" is
received.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.9.3 CF_MENUSIZE Command
Command
“CF_MENUSIZE_%1” [CR]
%1
“NORMAL” -------------------- Select Menu size to Normal.
“DOUBLE” --------------------- Select Menu size to Double.
Details
Select Menu size. (Valid only when in the normal Power ON status.)
The status set by this command is stored in EEPROM and the setting remains
even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]