PLC-HF15000L Expand Serial Command Functional Specifications 9.10.14 CR_BLEND Command Command "CR_BLEND" [CR] Details Get all values set for Width in Edge blending Acceptable "000_%1_%2_%3_%4" [CR] Left width data comes first, and then one space, after that right width data is followed. Response %1, %2, %3, %4 Unacceptable %1 = Left width %2 = Right width %3 = Top width %4 = Bottom width e.g. "0100_0100_0100_0100"[CR] Left = width 100 Right = width 100 Top = width 100 Bottom = width 100 "Error Code" [CR] 9.10.15 CR_BLENDSTART Command Command "CR_BLENDSTART" [CR] Details Get all values set for Start in Edge blending Acceptable "000_%1_%2_%3_%4" [CR] Left width data comes first, and then one space, after that right width data is followed. Response %1, %2, %3, %4 %1 = Left width %2 = Right width %3 = Top width %4 = Bottom width e.g. "0100_0100_0100_0100"[CR] Left = width 100 Right = width 100 Top = width 100 Bottom = width 100 Unacceptable "Error Code" [CR] 9.10.16 CR_BLENDBLK Command Command "CR_BLENDBLK" [CR] Details Get all values set for Black level in Edge blending Acceptable "000_%1_%2_%3" [CR] Response %1, %2, %3 Data of red comes first, and then one space, after that data of green is followed. %1 = Red %2 = Green %3 = Blue e.g. "0100_0100_0100"[CR] Red = 100 Green = 100 Blue = 100 Unacceptable "Error Code" [CR] 90/105