Sanyo PLC-HF15000L RS232 Expand - Page 70

CR_CLAMP Command, 5.6 CR_DDOTS Command, 5.7 CR_DLINE Command

Page 70 highlights

PLC-HF15000L Expand Serial Command Functional Specifications 9.5.5 CR_CLAMP Command Command "CR_CLAMP" [CR] Details Get value of Clamp Acceptable "000_%1" [CR] Response %1 Unacceptable "0000" - " 4095" "Error Code" [CR When command is invalid in the given condition (such as being selected input) "?" [CR] --------- When unknown command is received 9.5.6 CR_DDOTS Command Command "CR_DDOTS" [CR] Details Get value of Display Dots Acceptable "000_%1" [CR] Response %1 Unacceptable "0256"-"nnnn" (nnnn = Total Dots - Position H) "Error Code" [CR When command is invalid in the given condition (such as being selected input) "?" [CR] --------- When unknown command is received 9.5.7 CR_DLINE Command Command "CR_DLINE" [CR] Details Get value of Display Line Acceptable "000_%1" [CR] Response %1 Unacceptable "0100" - " nnnn" (nnnn = Total Line - Position V) "Error Code" [CR When command is invalid in the given condition (such as being selected input) "?" [CR] --------- When unknown command is received 70/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF15000L
Expand Serial Command Functional Specifications
70/105
9.5.5 CR_CLAMP Command
Command
“CR_CLAMP” [CR]
Details
Get value of Clamp
Acceptable
“000_%1” [CR]
%1
“0000” – “ 4095”
Response
Unacceptable
“Error Code” [CR] --------------
When command is invalid in the
given condition (such as being selected input)
“?” [CR] --------- When unknown command is received
9.5.6 CR_DDOTS Command
Command
“CR_DDOTS” [CR]
Details
Get value of Display Dots
Acceptable
“000_%1” [CR]
%1
“0256”-”nnnn”
(nnnn = Total Dots – Position H)
Response
Unacceptable
“Error Code” [CR] --------------
When command is invalid in the
given condition (such as being selected input)
“?” [CR] --------- When unknown command is received
9.5.7 CR_DLINE Command
Command
“CR_DLINE” [CR]
Details
Get value of Display Line
Acceptable
“000_%1” [CR]
%1
“0100” – “ nnnn”
(nnnn = Total Line – Position V)
Response
Unacceptable
“Error Code” [CR] --------------
When command is invalid in the
given condition (such as being selected input)
“?” [CR] --------- When unknown command is received