Yamaha CS6R Owner's Manual - Page 165

CTRL Knobs [A] to [C], CTRL Scene Controller Scene CS6x, CTRL Other Controller Other

Page 165 highlights

s BCCurve (TG Breath Curve) Set the Breath Curve determining how the strength with which you blow into the Breath Controller will affect the sound output. t Settings: thru, soft, hard, wide Adjusted Breath Control thru Received Breath Control Adjusted Breath Control soft Received Breath Control Adjusted Breath Control s CC# (Control Number) Assign MIDI Control Change Numbers to Assignable Knobs [A] to [C]. t Settings: 000 ~ 095 (see the separate Data List for details) s Dest (Control Destination) Set the function to be controlled by Assignable Knobs [A] to [C]. t Settings: see the separate Data List for details The positions of Knobs [A]/[B]/[C] can be memorized for each Voice, Performance and Phrase Clip. If a Master Equalizer parameter is selected as the destination, the M.EQ settings of "vce" (in Utility Mode) are increased/decreased Using Knobs [A]/[B]/[C]. CTRL Scene (Controller Scene) (CS6x) Set the SCENE [CONTROL] knob parameters. CTRL Scene) Scene Control Sys 65[Porta Sw] hard Received Breath Control Adjusted Breath Control s Scene Control (Scene Control Number) Assign a MIDI Control Change Number to the SCENE [CONTROL] knob. t Settings: 000 ~ 095 (see the separate Data List for details) wide Received Breath Control CTRL (System Controller) In Voice Mode, you can set parameters for Controllers. The following five screens are available. CTRL KnobA (Control Knob [A]) CTRL KnobB (Control Knob [B]) CTRL KnobC (Control Knob [C]) CTRL Scene (Control Scene) CTRL Other (Control Other) CTRL Knobs [A] to [C] You can assign various control functions to Assignable Knobs [A] to [C] on the front panel. CTRL KnobA) CC# Sys 67[--------] Dest EQLow-G CTRL Other (Controller Other) Set the Foot Switch and Foot Volume parameters. CTRL Other) FS Sys 65[Porta Sw] FV volume s FS (Foot Switch) Assign a Control Change message to the Foot Switch. t Settings: 000 ~ 100 (000/032 = off, 096 = Arp Sw, 097 = Arpeggio Hold, 098 = Sequence PLAY/STOP, 099/100 = Program Change INC/DEC) The available settings for the CS6R are 000 to 095. Details about Control Numbers and Control Changes are given in the separate Data List. s FV (Foot Volume) (CS6x only) Select whether Foot Volume controls the Main Volume or Expression parameter. t Settings: volume (Main Volume), expression Details about the Main Volume and Expression parameters are given in the separate Data List. Utility Mode 165

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

165
Utility Mode
BCCurve (TG Breath Curve)
Set the Breath Curve determining how the strength
with which you blow into the Breath Controller will
affect the sound output.
Settings:
thru, soft, hard, wide
CTRL (System Controller)
In Voice Mode, you can set parameters for Controllers.
The following five screens are available.
CTRL KnobA (Control Knob [A])
CTRL KnobB (Control Knob [B])
CTRL KnobC (Control Knob [C])
CTRL Scene (Control Scene)
CTRL Other (Control Other)
CTRL Knobs [A] to [C]
You can assign various control functions to Assignable
Knobs [A] to [C] on the front panel.
CTRL KnobA) CC# Dest
Sys 67[--------] EQLow-G
wide
Adjusted Breath Control
Received Breath Control
hard
Adjusted Breath Control
Received Breath Control
soft
Adjusted Breath Control
Received Breath Control
thru
Adjusted Breath Control
Received Breath Control
CC# (Control Number)
Assign MIDI Control Change Numbers to Assignable
Knobs [A] to [C].
Settings:
000 ~ 095 (see the separate Data List for
details)
Dest (Control Destination)
Set the function to be controlled by Assignable
Knobs [A] to [C].
Settings:
see the separate Data List for details
The positions of Knobs [A]/[B]/[C] can be memorized
for each Voice, Performance and Phrase Clip.
If a Master Equalizer parameter is selected as the
destination, the M.EQ settings of “vce” (in Utility
Mode) are increased/decreased Using Knobs
[A]/[B]/[C].
CTRL Scene (Controller Scene) (CS6x)
Set the SCENE [CONTROL] knob parameters.
Scene Control (Scene Control Number)
Assign a MIDI Control Change Number to the
SCENE [CONTROL] knob.
Settings:
000 ~ 095 (see the separate Data List for
details)
CTRL Other (Controller Other)
Set the Foot Switch and Foot Volume parameters.
FS (Foot Switch)
Assign a Control Change message to the Foot Switch.
Settings:
000 ~ 100 (000/032 = off, 096 = Arp Sw, 097
= Arpeggio Hold, 098 = Sequence PLAY/STOP,
099/100 = Program Change INC/DEC)
The available settings for the CS6R are 000 to 095.
Details about Control Numbers and Control Changes
are given in the separate Data List.
FV (Foot Volume) (CS6x only)
Select whether Foot Volume controls the Main
Volume or Expression parameter.
Settings:
volume (Main Volume), expression
Details about the Main Volume and Expression
parameters are given in the separate Data List.
CTRL Other) FS FV
Sys 65[Porta Sw] volume
CTRL Scene) Scene Control
Sys 65[Porta Sw]